Literature DB >> 22136078

Prospective use of subtraction ictal SPECT coregistered to MRI (SISCOM) in presurgical evaluation of epilepsy.

Tim J von Oertzen1, Florian Mormann, Horst Urbach, Karl Reichmann, Roy Koenig, Hans Clusmann, Hans Juergen Biersack, Christian E Elger.   

Abstract

PURPOSE: In patients with drug-refractory focal epilepsy, nonlesional magnetic resonance imaging (MRI) or discordant data of presurgical standard investigations leads to failure generating a sufficient hypothesis for electrode implantation or epilepsy surgery. The seizure-onset zone can be further investigated by subtraction ictal single-photon emission computed tomography (SPECT) coregistered to MRI (SISCOM). This is an observational study of a large consecutive cohort of patients undergoing prospective SISCOM to generate hypothesis for electrode implantation or site of epilepsy surgery.
METHODS: One hundred seventy-five consecutive patients undergoing presurgical evaluation with either nonlesional MRI or discordant data of standard investigations preventing the generation of hypothesis for seizure onset were evaluated with SISCOM. Results were compared to gold standard for seizure onset detection, either electrocorticography (ECoG) and/or postoperative outcome. KEY
FINDINGS: One hundred thirty patients had successful SPECT injection. Hypothesis for electrode implantation/site of surgery was generated in 74 patients. Forty patients had gold standard comparison. Twenty-eight patients underwent resective surgery. SISCOM was concordant to site of surgery in 82%. An additional 12 patients underwent invasive EEG monitoring but were not suitable for surgery. SISCOM was concordant multifocal in 75%. Two years postsurgical follow-up of 26 patients showed favorable outcome in 22 (Engel class I and class II). SIGNIFICANCE: SISCOM is a highly valuable diagnostic tool to localize the seizure-onset zone in nonlesional and extratemporal epilepsies. Outcome in this patient group was unexpectedly good, even in patients with nonlesional MRI. The high correlation with ECoG and site of successful surgery is a strong indicator that outcome prediction in this patient group should be adapted accordingly, which may encourage more patients to undergo electrode implantation and subsequent successful surgery. Statistical analysis showed that SISCOM with shorter duration of seizures, focal seizures, and lesional MRI was more likely to generate implantation hypothesis. Wiley Periodicals, Inc.
© 2011 International League Against Epilepsy.

Entities:  

Mesh:

Year:  2011        PMID: 22136078     DOI: 10.1111/j.1528-1167.2011.03219.x

Source DB:  PubMed          Journal:  Epilepsia        ISSN: 0013-9580            Impact factor:   5.864


  18 in total

Review 1.  Neuroimaging of epilepsy.

Authors:  Fernando Cendes; William H Theodore; Benjamin H Brinkmann; Vlastimil Sulc; Gregory D Cascino
Journal:  Handb Clin Neurol       Date:  2016

Review 2.  Anaesthesia for epilepsy surgery.

Authors:  C M Larkin; D F O'Brien; D Maheshwari
Journal:  BJA Educ       Date:  2019-09-26

Review 3.  Basic mechanisms of epileptogenesis in pediatric cortical dysplasia.

Authors:  Sara Abdijadid; Gary W Mathern; Michael S Levine; Carlos Cepeda
Journal:  CNS Neurosci Ther       Date:  2014-11-18       Impact factor: 5.243

4.  Connectivity in ictal single photon emission computed tomography perfusion: a cortico-cortical evoked potential study.

Authors:  Simon Tousseyn; Balu Krishnan; Zhong I Wang; Sattawut Wongwiangjunt; Chetan S Nayak; John C Mosher; Guiyun Wu; Wim Van Paesschen; Richard M Leahy; Jorge A Gonzalez-Martinez; Juan Bulacio; Imad M Najm; Andreas V Alexopoulos; Dileep R Nair
Journal:  Brain       Date:  2017-07-01       Impact factor: 13.501

5.  Neuroimaging in the definition and organization of the epilepsies: we're not there yet.

Authors:  Jason S Hauptman; Noriko Salamon; Gary W Mathern
Journal:  Epilepsia       Date:  2012-07       Impact factor: 5.864

6.  The promise of subtraction ictal SPECT co-registered to MRI for improved seizure localization in pediatric epilepsies: Affecting factors and relationship to the surgical outcome.

Authors:  Catherine Stamoulis; Nishant Verma; Himanshu Kaulas; Jonathan J Halford; Frank H Duffy; Phillip L Pearl; S Ted Treves
Journal:  Epilepsy Res       Date:  2016-11-30       Impact factor: 3.045

Review 7.  Towards precision medicine in epilepsy surgery.

Authors:  Pingping Jin; Dongyan Wu; Xiaoxuan Li; Liankun Ren; Yuping Wang
Journal:  Ann Transl Med       Date:  2016-01

8.  MNI SISCOM: an Open-Source Tool for Computing Subtraction Ictal Single-Photon Emission CT Coregistered to MRI.

Authors:  Jeremy T Moreau; Christine Saint-Martin; Sylvain Baillet; Roy W R Dudley
Journal:  J Digit Imaging       Date:  2021-02-18       Impact factor: 4.056

9.  Localization value of magnetoencephalography interictal spikes in adult nonlesional neocortical epilepsy.

Authors:  Woorim Jeong; Chun Kee Chung; June Sic Kim
Journal:  J Korean Med Sci       Date:  2012-10-30       Impact factor: 2.153

10.  Prognostic Role of Functional Neuroimaging after Multilobar Resection in Patients with Localization-Related Epilepsy.

Authors:  Eun Bin Cho; Eun Yeon Joo; Dae-Won Seo; Seung-Chyul Hong; Seung Bong Hong
Journal:  PLoS One       Date:  2015-08-25       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.