| Literature DB >> 22135609 |
Ji Young Kwon1, Won Sik Yoon, Gui Se Ra Lee, Sa Jin Kim, Jong Chul Shin, In Yang Park.
Abstract
PURPOSE: To compare umbilical arterial gas parameters in the second twin of twin pregnancies according to the mode of delivery.Entities:
Keywords: cesarean delivery; inter-twin delivery interval; twin pregnancy; umbilical arterial gas parameters; vaginal delivery
Mesh:
Year: 2011 PMID: 22135609 PMCID: PMC3204432 DOI: 10.7150/ijms.8.643
Source DB: PubMed Journal: Int J Med Sci ISSN: 1449-1907 Impact factor: 3.738
Maternal and obstetric characteristics of the study group according to mode of delivery.
| Vaginal delivery (N=39) | Cesarean delivery (N=40) | ||
|---|---|---|---|
| Maternal age | 30.5±3.2 | 32.5±3.0 | 0.007 |
| Parity (nulliparaous women) | 22 (56.4%) | 31 (77.5%) | 0.046 |
| G - age* at delivery (weeks) | 37.0±2.1 | 36.9±1.4 | 0.751 |
| Birth weight at delivery (g) | |||
| First /second twins | 2517.2±344.6 / 2507.2±338.3 | 2647.3±385.4 / 2545.1±359.3 | 0.451 |
| Twin-to twin delivery time interval (min) | |||
| Mean (min) | 8.2±8.2 | 1.6 ± 0.6 | < 0.001 |
| > 10 min | 11 (28.2%) | 0 (0%) | <0.001 |
| Sex (male) first /second twins | 19(48.7%) / 20 (51.3%) | 18 (45.0%) / 22 (55.0%) | 0.799 |
*Gestational age
Values are presented as mean ± standard deviation or number of patients (%)
P values were derived from student t test and Chi-square test
Mean values of umbilical artery blood gas parameters and Apgar scores of newborns according to the type of delivery mood.
| Vaginal delivery (N=39) | Cesarean delivery (N=40) | |||
|---|---|---|---|---|
| First twins | Second twins | First twins | Second twins | |
| pH | 7.28±0.10 | 7.25±0.10 | 7.30±0.06 | 7.28±0.07 |
| pH < 7.20 | 5 (12.8%) | 8 (20.5%) | 1 (2.5%) | 6 (15.0%) |
| pCO2 (mmHg) | 46.58±50.93 | 60.08±9.26 | 45.65±9.03 | 48.24±9.42 |
| HCO3 (mEq/L) | 21.39±21.88 | 22.26±3.33 | 21.87±3.59 | 22.09±3.43 |
| Base deficit (mEq/L) | 5.63±5.83 | 5.23±2.73 | 4.74±3.71 | 4.79±3.45 |
| 1 min < 7 | 6 (15.4%) | 6 (15.4%) | 7 (17.5%) | 8 (20.0%) |
| 5 min < 7 | 2 (5.1%) | 4 (10.3%) | 1 (2.5%) | 1 (2.5%) |
Values are presented as mean ± standard deviation or number of patients (%)
Inter-twin differences of umbilical arterial blood gas parameters and Apgar scores according to the delivery mode.
| Vaginal delivery (N=39) | Cesarean delivery (N=40) | ||
|---|---|---|---|
| pH | 0.02 ± 0.07 | 0.02 ± 0.05 | 0.762 |
| Decrease of pH value >0.005 | 13 (33.3%) | 10 (25.0%) | 0.415 |
| pCO2 (mmHg) | -3.35 ± 8.56 | -2.58 ± 9.25 | 0.707 |
| HCO3 (mEq/L) | -0.46 ± 2.34 | -0.22±2.98 | 0.697 |
| Base deficit (mEq/L) | 0.01±2.20 | -0.16±2.80 | 0.772 |
| Difference at 1 min ≥ 2 | 8 (20.5%) | 2 (5.0%) | 0.048 |
| Difference at 5 min ≥ 1 | 15 (38.5%) | 7 (17.5%) | 0.038 |
All values are the differences between first and second twins
Values are presented as mean ± standard deviation or number of patients (%)
P values were derived from student t test, Chi-square test and Fisher's exact test
Inter-twin differences of umbilical arterial blood gas parameters and Apgar scores in cases which inter-twin delivery interval was less than 10 min.
| Vaginal delivery (N=27) | Cesarean delivery (N=40) | ||
|---|---|---|---|
| pH | 0.01 ± 0.68 | 0.02 ± 0.06 | 0.599 |
| Decrease of pH value >0.005 | 13 (33.3%) | 10 (25.0%) | 0.870 |
| pCO2 (mmHg) | -2.22 ± 8.56 | -2.59 ± 9.26 | 0.870 |
| HCO3 (mEq/L) | -0.73 ± 2.53 | -0.22±2.98 | 0.475 |
| Base deficit (mEq/L) | -0.58±1.86 | -0.16±2.86 | 0.493 |
| Difference at 1 min ≥ 2 | 2 (7.4%) | 2 (5.0%) | 1.000 |
| Difference at 5 min ≥ 1 | 9 (33.3%) | 7 (17.5%) | 0.136 |
All values are the differences between first and second twins
Values are presented as mean ± standard deviation or number of patients (%)
P values were derived from student t test, Chi-square test and Fisher's exact test