Literature DB >> 22135546

The effect of delayed transportation of blood samples on serum bilirubin values in neonates.

Poovendran Saththasivam1, Kirtanaa Voralu, Noraida Ramli, Mohd Rafi Mustapha, Julia Omar, Hans Van Rostenberghe.   

Abstract

BACKGROUND: Delays in transporting blood samples may cause inaccurate results. Samples may be exposed to light or heat during delays, resulting in the degradation of analytes, for example, bilirubin. This study was done to determine the effect of delays in the transportation of blood samples on serum bilirubin test results.
METHODS: Samples taken from neonates admitted to a tertiary hospital with jaundice were included in the study. The samples were collected through venipuncture in 3 labelled containers. The first container was sent immediately to the laboratory, while the second and third containers were sent after being kept in the ward for 1 and 3 hours, respectively. Bilirubin values were measured colourimetrically at a wavelength of 578 nm using a Roche Hitachi 912 Chemistry Analyser upon arrival in the laboratory.
RESULTS: A total of 36 serum samples were studied. The mean of the indirect bilirubin measurements for 0-, 1-, and 3-hour samples were 174 (SD 68.65), 186.97 (SD 60.47), and 184.56 (SD 66.93), respectively. There was a significant difference in the mean indirect bilirubin measurement of 1-hour samples (P = 0.047, 95% CI -24.66 to -1.18) and 3-hour samples (P = 0.045, 95% CI -19.77 to -0.23) compared with 0-hour samples. There were no significant differences observed in either the mean total bilirubin or the mean direct bilirubin measurements of different time intervals.
CONCLUSION: This study confirms that delays in the transportation of blood samples influence the bilirubin test results.

Entities:  

Keywords:  bilirubin; medical sciences; neonatal jaundice; specimen handling; time factors; transportation

Year:  2010        PMID: 22135546      PMCID: PMC3216170     

Source DB:  PubMed          Journal:  Malays J Med Sci        ISSN: 1394-195X


  3 in total

1.  Neonatal bilirubin testing practices: reports from 312 laboratories enrolled in the Colege of American Pathologists Excel Proficiency Testing Program.

Authors:  J C Dale; H J Hamrick
Journal:  Arch Pathol Lab Med       Date:  2000-10       Impact factor: 5.534

2.  Studies of the stability of 18 chemical constituents of human serum.

Authors:  S S Wilson; R A Guillan; E V Hocker
Journal:  Clin Chem       Date:  1972-12       Impact factor: 8.327

3.  Effects of transportation and delay in processing on the stability of nutritional and metabolic biomarkers.

Authors:  J M Murphy; R W Browne; L Hill; G F Bolelli; C Abagnato; F Berrino; J Freudenheim; M Trevisan; P Muti
Journal:  Nutr Cancer       Date:  2000       Impact factor: 2.900

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.