Literature DB >> 22135318

Non-contact mapping system accurately localizes right-sided accessory pathways in type B Wolff-Parkinson-White syndrome.

Taku Nishida1, Tamio Nakajima, Kazuaki Kaitani, Akihiro Takitsume, Tsunenari Soeda, Satoshi Okayama, Satoshi Somekawa, Yukiji Takeda, Ken-Ichi Ishigami, Hiroyuki Kawata, Rika Kawakami, Manabu Horii, Shiro Uemura, Yoshihiko Saito.   

Abstract

AIMS: Ablation of right-sided accessory pathways (APs) is sometimes challenging because several anatomical features of the tricuspid annulus (TA) and surrounding structures differ from those of the mitral annulus. This study investigated the electrophysiological characteristics and efficacy of a non-contact mapping (NCM) system for catheter ablation of right-sided APs. METHODS AND
RESULTS: We examined nine APs in six consecutive patients who underwent catheter ablation of right-sided APs with NCM. In Case 6, we compared NCM with contact activation mapping. Three of six patients had two APs, and one of these had previously failed ablation. We observed atrial activation during sinus rhythm or atrial pacing using a multiple-electrode array (MEA) deployed in the right atrium near the TA. Non-contact mapping identified the AP location as a peri-TA breakout point that appeared prior to or simultaneously with the delta wave onset in all APs. In Case 6 we confirmed that the peri-TA breakout identified by NCM corresponded to the earliest ventricular activation identified by contact mapping. We successfully ablated nine APs by radiofrequency (RF) energy application to the breakout sites, while one AP located just above the pole of the MEA required additional conventionally guided mapping and ablation. The mean RF duration was 189.8 ± 119.0 s. After 33.2 ± 9.4 months of follow-up, one para-hisian AP and one right lateral AP recurred, but these were successfully ablated in a second procedure using NCM.
CONCLUSION: Non-contact mapping was able to identify the location of right-sided APs accurately and quickly.

Entities:  

Mesh:

Year:  2011        PMID: 22135318     DOI: 10.1093/europace/eur369

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214