Literature DB >> 22135248

Extracranial measurements of amide proton transfer using exchange-modulated point-resolved spectroscopy (EXPRESS).

Simon Walker-Samuel1, S Peter Johnson, Barbara Pedley, Mark F Lythgoe, Xavier Golay.   

Abstract

Chemical exchange saturation transfer (CEST) imaging has been used experimentally in a large range of applications. However, full quantification of CEST effects in vivo using standard imaging sequences is time consuming as a large number of saturation frequency offsets, each followed by an imaging readout, are required to define a z spectrum. Furthermore, outside the brain, the presence of fat can confound the interpretation of z spectra. A novel acquisition and post-processing technique is presented in this study, named exchange-modulated point-resolved spectroscopy (EXPRESS), which aims to address these limitations and to enable spatially localised, high signal-to-noise measurements of CEST effects in vivo. Using amide proton exchange (APT) measurements in tumours, it is demonstrated that the acquisition of two-dimensional EXPRESS spectra composed of chemical shift and saturation frequency offset dimensions allows the correction of CEST data containing both fat and water signals, which is a common confounding property of tissues found outside the brain.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22135248     DOI: 10.1002/nbm.1798

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  4 in total

1.  In vivo imaging of glucose uptake and metabolism in tumors.

Authors:  Simon Walker-Samuel; Rajiv Ramasawmy; Francisco Torrealdea; Marilena Rega; Vineeth Rajkumar; S Peter Johnson; Simon Richardson; Miguel Gonçalves; Harold G Parkes; Erik Arstad; David L Thomas; R Barbara Pedley; Mark F Lythgoe; Xavier Golay
Journal:  Nat Med       Date:  2013-07-07       Impact factor: 53.440

2.  Chemical exchange saturation transfer imaging in hepatic encephalopathy.

Authors:  Helge Jörn Zöllner; Markus Butz; Markus Jördens; Nur-Deniz Füllenbach; Dieter Häussinger; Benjamin Schmitt; Hans-Jörg Wittsack; Alfons Schnitzler
Journal:  Neuroimage Clin       Date:  2019-03-04       Impact factor: 4.881

3.  Non-invasive imaging of disrupted protein homeostasis induced by proteasome inhibitor treatment using chemical exchange saturation transfer MRI.

Authors:  Yanan Zhu; Rajiv Ramasawmy; Sean Peter Johnson; Valerie Taylor; Alasdair Gibb; R Barbara Pedley; Nibedita Chattopadhyay; Mark F Lythgoe; Xavier Golay; Daniel Bradley; Simon Walker-Samuel
Journal:  Sci Rep       Date:  2018-10-10       Impact factor: 4.379

4.  Combining chemical exchange saturation transfer and 1 H magnetic resonance spectroscopy for simultaneous determination of metabolite concentrations and effects of magnetization exchange.

Authors:  Maike Hoefemann; André Döring; Nicole Damara Fichtner; Roland Kreis
Journal:  Magn Reson Med       Date:  2020-11-05       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.