Literature DB >> 22135071

Influence of the arterial input function on absolute and relative perfusion-weighted imaging penumbral flow detection: a validation with ¹⁵O-water positron emission tomography.

Olivier Zaro-Weber1, Walter Moeller-Hartmann, Wolf-Dieter Heiss, Jan Sobesky.   

Abstract

BACKGROUND AND
PURPOSE: Perfusion-weighted imaging maps are used to identify critical hypoperfusion in acute stroke. However, quantification of perfusion may depend on the choice of the arterial input function (AIF). Using quantitative positron emission tomography we evaluated the influence of the AIF location on maps of absolute and relative perfusion-weighted imaging to detect penumbral flow (PF; <20 mL/100 g/min on positron emission tomography(CBF)) in acute stroke.
METHODS: In 22 patients with acute stroke the AIF was placed at 7 sites (M1, M2, M3 ipsi- and contralateral and internal carotid artery-M1 contralateral to the infarct). Comparative (15)O-water positron emission tomography and AIF-dependent perfusion-weighted imaging (cerebral blood flow, cerebral blood volume, mean transit time, and time to maximum) were performed. A receiver operating characteristic curve analysis described the threshold independent performance (area under the curve) of the perfusion-weighted maps for all 7 AIF locations and identified the best AIF-dependent absolute and relative thresholds to identify PF. These results were compared with AIF-independent time-to-peak maps.
RESULTS: Quantitative perfusion-weighted imaging maps of cerebral blood flow and time to maximum performed best. For PF detection, AIF placement did significantly influence absolute PF thresholds. However, AIF placement did not influence (1) the threshold independent performance; and (2) the relative PF thresholds. AIF placement in the proximal segment of the contralateral middle cerebral artery (cM1) was preferable for quantification.
CONCLUSIONS: AIF-based maps of cerebral blood flow and time to maximum were most accurate to detect the PF threshold. The AIF placement significantly altered absolute PF thresholds and showed best agreement with positron emission tomography for the cM1 segment. The performance of relative PF thresholds, however, was not AIF location-dependent and might be along with AIF-independent time-to-peak maps, more suitable than absolute PF thresholds in acute stroke if detailed postprocessing is not feasible.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22135071     DOI: 10.1161/STROKEAHA.111.635458

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  9 in total

1.  3D GRASE pulsed arterial spin labeling at multiple inflow times in patients with long arterial transit times: comparison with dynamic susceptibility-weighted contrast-enhanced MRI at 3 Tesla.

Authors:  Steve Z Martin; Vince I Madai; Federico C von Samson-Himmelstjerna; Matthias A Mutke; Miriam Bauer; Cornelius X Herzig; Stefan Hetzer; Matthias Günther; Jan Sobesky
Journal:  J Cereb Blood Flow Metab       Date:  2014-11-19       Impact factor: 6.200

2.  Increased hippocampal blood volume and normal blood flow in schizophrenia.

Authors:  Pratik Talati; Swati Rane; Jack Skinner; John Gore; Stephan Heckers
Journal:  Psychiatry Res       Date:  2015-04-03       Impact factor: 3.222

3.  MRI-based mismatch detection in acute ischemic stroke: Optimal PWI maps and thresholds validated with PET.

Authors:  Olivier Zaro-Weber; Walter Moeller-Hartmann; Dora Siegmund; Alexandra Kandziora; Alexander Schuster; Wolf-Dieter Heiss; Jan Sobesky
Journal:  J Cereb Blood Flow Metab       Date:  2016-12-28       Impact factor: 6.200

4.  Mapping of cerebral metabolic rate of oxygen using dynamic susceptibility contrast and blood oxygen level dependent MR imaging in acute ischemic stroke.

Authors:  Alexandra S Gersing; Monika Ankenbrank; Benedikt J Schwaiger; Vivien Toth; Insa Janssen; Hendrik Kooijman; Silke Wunderlich; Jan S Bauer; Claus Zimmer; Christine Preibisch
Journal:  Neuroradiology       Date:  2015-09-12       Impact factor: 2.804

5.  Enhancing performance of a computed tomography perfusion software for improved prediction of final infarct volume in acute ischemic stroke patients.

Authors:  Ryan A Rava; Kenneth V Snyder; Maxim Mokin; Muhammad Waqas; Alexander R Podgorsak; Ariana B Allman; Jillian Senko; Mohammad Mahdi Shiraz Bhurwani; Yiemeng Hoi; Jason M Davies; Elad I Levy; Adnan H Siddiqui; Ciprian N Ionita
Journal:  Neuroradiol J       Date:  2021-01-21

6.  Penumbra detection in acute stroke with perfusion magnetic resonance imaging: Validation with 15 O-positron emission tomography.

Authors:  Olivier Zaro-Weber; Hermann Fleischer; Lucas Reiblich; Alexander Schuster; Walter Moeller-Hartmann; Wolf-Dieter Heiss
Journal:  Ann Neurol       Date:  2019-04-22       Impact factor: 10.422

7.  A Quantitative Comparison of Clinically Employed Parameters in the Assessment of Acute Cerebral Ischemia Using Dynamic Susceptibility Contrast Magnetic Resonance Imaging.

Authors:  Christian Nasel; Uros Klickovic; Heike-Marie Kührer; Kersten Villringer; Jochen B Fiebach; Arno Villringer; Ewald Moser
Journal:  Front Physiol       Date:  2019-01-15       Impact factor: 4.566

8.  Influence of the arterial input sampling location on the diagnostic accuracy of cardiovascular magnetic resonance stress myocardial perfusion quantification.

Authors:  Xenios Milidonis; Russell Franks; Torben Schneider; Javier Sánchez-González; Eva C Sammut; Sven Plein; Amedeo Chiribiri
Journal:  J Cardiovasc Magn Reson       Date:  2021-03-29       Impact factor: 5.364

9.  Normalised time-to-peak-distribution curves correlate with cerebral white matter hyperintensities - Could this improve early diagnosis?

Authors:  Christian Nasel; Roland Boubela; Klaudius Kalcher; Ewald Moser
Journal:  J Cereb Blood Flow Metab       Date:  2016-07-20       Impact factor: 6.200

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.