The influence of fixation peg design on the shear stability of prosthetic implants.

N J Giori1, G S Beaupré, D R Carter.   

Abstract

The variety of fixation peg designs existing on prosthetic implants indicates uncertainty regarding the optimum design of fixation pegs for the reduction of stress and relative motion at the bone-implant interface. Fixation pegs have a number of important functions on a prosthesis, one of which is to reduce shear stress and shear displacement at the bone-implant interface. This is a parametric study intended to identify trends in the shear stability of prostheses incorporating a range of fixation peg designs. The parameters varied included the number of fixation pegs on a surface, the size of the pegs, and the aspect ratio (length/diameter) of the pegs. Mechanical tests were performed on urethane foam blocks with mechanical properties comparable to trabecular bone. The results indicated the following: (a) Fixation pegs act independently in resisting shearing force if they are spaced sufficiently far apart. (b) For any given shear displacement, smaller pegs generate a greater resistive shear force per unit of peg projected area in the direction of the applied load than larger pegs having the same aspect ratio. (c) Smaller diameter pegs cause the supporting material to yield at lower displacements. (d) Pegs with a high aspect ratio provide high shear stability with a minimum amount of bone removed, but may bend if the aspect ratio becomes excessive. (e) Smaller, slender pegs generate a greater resistive shear force at a given displacement per unit of peg volume than larger, lower aspect ratio pegs.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2213346     DOI: 10.1002/jor.1100080615

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  5 in total

1.  Porous metals and alternate bearing surfaces in shoulder arthroplasty.

Authors:  Shannon R Carpenter; Ivan Urits; Anand M Murthi
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  Posterior glenoid wear in total shoulder arthroplasty: eccentric anterior reaming is superior to posterior augment.

Authors:  Tim Wang; Geoffrey D Abrams; Anthony W Behn; Derek Lindsey; Nicholas Giori; Emilie V Cheung
Journal:  Clin Orthop Relat Res       Date:  2015-08-05       Impact factor: 4.176

3.  CT scan evaluation of glenoid component fixation: a prospective study of 27 minimally cemented shoulder arthroplasties.

Authors:  A Vidil; Ph Valenti; F Guichoux; J H Barthas
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-11-09

4.  Stability of small pegs for cementless implant fixation.

Authors:  Diogo M Geraldes; Ulrich Hansen; Jonathan Jeffers; Andrew A Amis
Journal:  J Orthop Res       Date:  2017-05-23       Impact factor: 3.494

Review 5.  A comparison of pegged vs. keeled glenoid components regarding functional and radiographic outcomes in anatomic total shoulder arthroplasty: a systematic review and meta-analysis.

Authors:  Arthur Welsher; Chetan Gohal; Kim Madden; Bruce Miller; Asheesh Bedi; Bashar Alolabi; Moin Khan
Journal:  JSES Open Access       Date:  2019-07-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.