Literature DB >> 22129572

Microextraction by packed sorbent for the analysis of pharmaceutical residues in environmental water samples by in situ derivatization-programmed temperature vaporizer-gas chromatography-mass spectrometry.

Gloria Grueiro Noche1, María Esther Fernández Laespada, José Luis Pérez Pavón, Bernardo Moreno Cordero, Soledad Muniategui Lorenzo.   

Abstract

The present work describes the development and validation of a method for the determination of five non-steroidal anti-inflammatory drugs (NSAIDs: clofibric acid, ibuprofen, naproxen, diclofenac and ketoprofen) in water samples. The fully automated method includes in situ aqueous derivatization followed by analyte enrichment by microextraction by packed sorbent (MEPS) coupled directly to programmed temperature vaporizer-gas chromatography-mass spectrometry (PTV-GC-MS). The MEPS variables, such as sample volume, elution solvent, elution volume, fill and injection speed and washing steps were optimized. It was possible to use the MEPS polymer (silica-C18) 250 times. Ibuprofen-d3 was used as internal standard. The reproducibility of the method, calculated as the relative standard deviation (RSD), was below 10% for all compounds. Detection limits in ultrapure water were between 3.0 and 110 ngL(-1) for ibuprofen and ketoprofen, respectively. External calibration was used in the determination of NSAIDs in several types of water samples, including tap, river, sea and influent and effluent wastewater. The results obtained revealed the presence of ibuprofen and naproxen in the influent wastewater sample and of naproxen in the effluent wastewater sample.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22129572     DOI: 10.1016/j.chroma.2011.10.094

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples.

Authors:  Maria Espina-Benitez; Lilia Araujo; Avismelsi Prieto; Alberto Navalón; José Luis Vílchez; Paola Valera; Ana Zambrano; Vincent Dugas
Journal:  Int J Environ Res Public Health       Date:  2017-07-07       Impact factor: 3.390

2.  [Research progress of microextraction by packed sorbent and its application in microvolume sample extraction].

Authors:  Jianan Wei; Molin Qin; Junchao Yang; Liu Yang
Journal:  Se Pu       Date:  2021-03
  2 in total