Literature DB >> 22129487

Cardiac computed tomography follow-up of left atrial appendage exclusion using the Amplatzer Cardiac Plug device.

Rohan S Poulter1, Jonathon Tang, John Jue, Reda Ibrahim, Savvas Nicolaou, John Mayo, Jacqueline Saw.   

Abstract

Functional exclusion of the left atrial appendage using transcatheter devices has been developed as an alternative therapy for atrial fibrillation in patients for whom formal anticoagulation is contraindicated. Noninvasive follow-up imaging of these devices is desirable. Transthoracic echocardiography has limitations due to field of view, limited available imaging windows, and metallic shadowing. Cardiac computed tomography has superior image resolution for determining device position and has the added capacity to noninvasively assess when exclusion of the appendage has occurred. This imaging technique is demonstrated in 2 cases of left atrial appendage closure using the Amplatzer Cardiac Plug (AGA Medical Corp, Plymouth, MN).
Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22129487     DOI: 10.1016/j.cjca.2011.09.005

Source DB:  PubMed          Journal:  Can J Cardiol        ISSN: 0828-282X            Impact factor:   5.223


  4 in total

1.  Cardiac CT angiography for device surveillance after endovascular left atrial appendage closure.

Authors:  Jacqueline Saw; Peter Fahmy; Peggy DeJong; Mathieu Lempereur; Ryan Spencer; Michael Tsang; Kenneth Gin; John Jue; John Mayo; Patrick McLaughlin; Savvas Nicolaou
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-04-06       Impact factor: 6.875

Review 2.  Role of Cardiac Imaging for Catheter-based Left Atrial Appendage Closure.

Authors:  Sébastien Marchandise; Joëlle Kefer; Jean-Benoît le Polain de Waroux; Christophe Scavée Jean-Louis Vanoverschelde
Journal:  J Atr Fibrillation       Date:  2013-06-30

Review 3.  Mechanical antithrombotic intervention by LAA occlusion in atrial fibrillation.

Authors:  Cheuk-Man Yu; Ahmed A Khattab; Stefan C Bertog; Alex P W Lee; Joey S W Kwong; Horst Sievert; Bernhard Meier
Journal:  Nat Rev Cardiol       Date:  2013-10-22       Impact factor: 32.419

Review 4.  Cardiac Plug I and Amulet Devices: Left Atrial Appendage Closure for Stroke Prophylaxis in Atrial Fibrillation.

Authors:  Akhil Parashar; E Murat Tuzcu; Samir R Kapadia
Journal:  J Atr Fibrillation       Date:  2015-04-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.