Literature DB >> 22128361

Using handheld plastic scintillator detectors to triage individuals exposed to a radiological dispersal device.

R P Manger1, N E Hertel, E A Burgett, A Ansari.   

Abstract

After a radiological dispersal device (RDD) event, people could become internally contaminated by inhaling dispersed radioactive particles. A rapid method to screen individuals who are internally contaminated is desirable. Such initial screening can help in prompt identification of those who are highly contaminated and in prioritising individuals for further and more definitive evaluation such as laboratory testing. The use of handheld plastic scintillators to rapidly screen those exposed to an RDD with gamma-emitting radionuclides was investigated in this study. The Monte Carlo N-Particle transport code was used to model two commercially available plastic scintillation detectors in conjunction with anthropomorphic phantom models to determine the detector response to inhaled radionuclides. Biokinetic models were used to simulate an inhaled radionuclide and its progression through the anthropomorphic phantoms up to 30 d after intake. The objective of the study was to see if internal contamination levels equivalent to 250 mSv committed effective dose equivalent could be detected using these instruments. Five radionuclides were examined: (60)Co, (137)Cs, (192)Ir, (131)I and (241)Am. The results demonstrate that all of the radionuclides except (241)Am could be detected when placing either one of the two plastic scintillator detector systems on the posterior right torso of the contaminated individuals.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22128361     DOI: 10.1093/rpd/ncr367

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  2 in total

1.  Use of Transportable Radiation Detection Instruments to Assess Internal Contamination from Intakes of Radionuclides Part II: Calibration Factors and ICAT Computer Program.

Authors:  Robert Anigstein; Richard H Olsher; Donald A Loomis; Armin Ansari
Journal:  Health Phys       Date:  2016-12       Impact factor: 1.316

2.  Use of Transportable Radiation Detection Instruments to Assess Internal Contamination From Intakes of Radionuclides Part I: Field Tests and Monte Carlo Simulations.

Authors:  Robert Anigstein; Michael C Erdman; Armin Ansari
Journal:  Health Phys       Date:  2016-06       Impact factor: 1.316

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.