OBJECTIVE: Cartilage wear is a feature of osteoarthritis and rheumatoid arthritis. Precise measurements of wear have been difficult. Cartilage wear caused by an artificial articulating joint surface is a well-known feature of hemiarthroplasties. The aim of this study was to demonstrate that radiostereometric analysis (RSA) may be used for three-dimensional measurements of cartilage wear in hemiarthroplasties of the hip. METHOD: We performed a phantom model study to assess the feasibility of a subsequent clinical trial. We showed that the motion of the prosthetic head relative to the pelvis was not influenced by the orientation of the prosthetic head. Twenty-two patients were randomised to treatment with a cemented or an uncemented hemiarthroplasty for an acute femoral neck fracture. Migration of the prosthetic head into the acetabulum was measured using RSA. RESULTS: A mean migration of the prosthetic head into the acetabulum of 0.62 mm was found at 3 months [95% confidence interval (CI): 0.27-0.97] and a further migration of -0.07 mm at 12 months (95% CI: -0.16-0.32). There were no differences between the groups in prosthetic migration or functional outcome. Between three and 12 months, there was no detectable cartilage wear during the first postoperative year. CONCLUSION: Whether the migration during the first 3 months represents a period of bedding in due to a harder opposite surface remains to be shown. RSA may be used for measurement of cartilage wear in hemiarthroplasties of the hip. This study demonstrates a highly precise method for measurements of cartilage wear.
RCT Entities:
OBJECTIVE:Cartilage wear is a feature of osteoarthritis and rheumatoid arthritis. Precise measurements of wear have been difficult. Cartilage wear caused by an artificial articulating joint surface is a well-known feature of hemiarthroplasties. The aim of this study was to demonstrate that radiostereometric analysis (RSA) may be used for three-dimensional measurements of cartilage wear in hemiarthroplasties of the hip. METHOD: We performed a phantom model study to assess the feasibility of a subsequent clinical trial. We showed that the motion of the prosthetic head relative to the pelvis was not influenced by the orientation of the prosthetic head. Twenty-two patients were randomised to treatment with a cemented or an uncemented hemiarthroplasty for an acute femoral neck fracture. Migration of the prosthetic head into the acetabulum was measured using RSA. RESULTS: A mean migration of the prosthetic head into the acetabulum of 0.62 mm was found at 3 months [95% confidence interval (CI): 0.27-0.97] and a further migration of -0.07 mm at 12 months (95% CI: -0.16-0.32). There were no differences between the groups in prosthetic migration or functional outcome. Between three and 12 months, there was no detectable cartilage wear during the first postoperative year. CONCLUSION: Whether the migration during the first 3 months represents a period of bedding in due to a harder opposite surface remains to be shown. RSA may be used for measurement of cartilage wear in hemiarthroplasties of the hip. This study demonstrates a highly precise method for measurements of cartilage wear.
Authors: Ragnhild Øydna Støen; Cathrine M Lofthus; Lars Nordsletten; Jan Erik Madsen; Frede Frihagen Journal: Clin Orthop Relat Res Date: 2013-08-24 Impact factor: 4.176
Authors: Olof G Sköldenberg; Helene Sjöö; Paula Kelly-Pettersson; Henrik Bodén; Thomas Eisler; André Stark; Olle Muren Journal: Acta Orthop Date: 2014-06-23 Impact factor: 3.717
Authors: Christoph Kolja Boese; Benjamin Buecking; Christopher Bliemel; Steffen Ruchholtz; Michael Frink; Philipp Lechler Journal: BMC Musculoskelet Disord Date: 2015-10-16 Impact factor: 2.362