Literature DB >> 22125181

Understanding the flowing atmospheric-pressure afterglow (FAPA) ambient ionization source through optical means.

Jacob T Shelley1, George C-Y Chan, Gary M Hieftje.   

Abstract

The advent of ambient desorption/ionization mass spectrometry (ADI-MS) has led to the development of a large number of atmospheric-pressure ionization sources. The largest group of such sources is based on electrical discharges; yet, the desorption and ionization processes that they employ remain largely uncharacterized. Here, the atmospheric-pressure glow discharge (APGD) and afterglow of a helium flowing atmospheric-pressure afterglow (FAPA) ionization source were examined by optical emission spectroscopy. Spatial emission profiles of species created in the APGD and afterglow were recorded under a variety of operating conditions, including discharge current, electrode polarity, and plasma-gas flow rate. From these studies, it was found that an appreciable amount of atmospheric H(2)O vapor, N(2), and O(2) diffuses through the hole in the plate electrode into the discharge to become a major source of reagent ions in ADI-MS analyses. Spatially resolved plasma parameters, such as OH rotational temperature (T(rot)) and electron number density (n(e)), were also measured in the APGD. Maximum values for T(rot) and n(e) were found to be ~1100 K and ~4×10(19) m(-3), respectively, and were both located at the pin cathode. In the afterglow, rotational temperatures from OH and N(2)(+) yielded drastically different values, with OH temperatures matching those obtained from infrared thermography measurements. The higher N(2)(+) temperature is believed to be caused by charge-transfer ionization of N(2) by He(2)(+). These findings are discussed in the context of previously reported ADI-MS analyses with the FAPA source. © American Society for Mass Spectrometry, 2011

Entities:  

Year:  2011        PMID: 22125181     DOI: 10.1007/s13361-011-0292-8

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  20 in total

1.  Versatile new ion source for the analysis of materials in open air under ambient conditions.

Authors:  Robert B Cody; James A Laramée; H Dupont Durst
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

2.  Surface analysis under ambient conditions using plasma-assisted desorption/ionization mass spectrometry.

Authors:  Lucy V Ratcliffe; Frank J M Rutten; David A Barrett; Terry Whitmore; David Seymour; Claire Greenwood; Yolanda Aranda-Gonzalvo; Steven Robinson; Martin McCoustra
Journal:  Anal Chem       Date:  2007-07-12       Impact factor: 6.986

3.  Atmospheric pressure chemical ionization source. 2. Desorption-ionization for the direct analysis of solid compounds.

Authors:  Francisco J Andrade; Jacob T Shelley; William C Wetzel; Michael R Webb; Gerardo Gamez; Steven J Ray; Gary M Hieftje
Journal:  Anal Chem       Date:  2008-03-18       Impact factor: 6.986

4.  Development of a dielectric barrier discharge ion source for ambient mass spectrometry.

Authors:  Na Na; Mengxia Zhao; Sichun Zhang; Chengdui Yang; Xinrong Zhang
Journal:  J Am Soc Mass Spectrom       Date:  2007-08-02       Impact factor: 3.109

5.  Established and emerging atmospheric pressure surface sampling/ionization techniques for mass spectrometry.

Authors:  Gary J Van Berkel; Sofie P Pasilis; Olga Ovchinnikova
Journal:  J Mass Spectrom       Date:  2008-09       Impact factor: 1.982

6.  Theoretical characterization of an atmospheric pressure glow discharge used for analytical spectrometry.

Authors:  Tom Martens; Diana Mihailova; Jan van Dijk; Annemie Bogaerts
Journal:  Anal Chem       Date:  2009-11-01       Impact factor: 6.986

7.  Phenol production in benzene/air plasmas at atmospheric pressure. Role of radical and ionic routes.

Authors:  Daniela Ascenzi; Pietro Franceschi; Graziano Guella; Paolo Tosi
Journal:  J Phys Chem A       Date:  2006-06-29       Impact factor: 2.781

8.  Ultrasensitive ambient mass spectrometric analysis with a pin-to-capillary flowing atmospheric-pressure afterglow source.

Authors:  Jacob T Shelley; Joshua S Wiley; Gary M Hieftje
Journal:  Anal Chem       Date:  2011-06-16       Impact factor: 6.986

9.  Elucidation of reaction mechanisms responsible for afterglow and reagent-ion formation in the low-temperature plasma probe ambient ionization source.

Authors:  George C-Y Chan; Jacob T Shelley; Joshua S Wiley; Carsten Engelhard; Ayanna U Jackson; R Graham Cooks; Gary M Hieftje
Journal:  Anal Chem       Date:  2011-04-28       Impact factor: 6.986

10.  Atmospheric pressure chemical ionization source. 1. Ionization of compounds in the gas phase.

Authors:  Francisco J Andrade; Jacob T Shelley; William C Wetzel; Michael R Webb; Gerardo Gamez; Steven J Ray; Gary M Hieftje
Journal:  Anal Chem       Date:  2008-03-18       Impact factor: 6.986

View more
  8 in total

1.  Mass spectrometry imaging as a tool for surgical decision-making.

Authors:  David Calligaris; Isaiah Norton; Daniel R Feldman; Jennifer L Ide; Ian F Dunn; Livia S Eberlin; R Graham Cooks; Ferenc A Jolesz; Alexandra J Golby; Sandro Santagata; Nathalie Y Agar
Journal:  J Mass Spectrom       Date:  2013-11       Impact factor: 1.982

2.  Molecular typing of Meningiomas by Desorption Electrospray Ionization Mass Spectrometry Imaging for Surgical Decision-Making.

Authors:  David Calligaris; Daniel R Feldman; Isaiah Norton; Priscilla K Brastianos; Ian F Dunn; Sandro Santagata; Nathalie Y R Agar
Journal:  Int J Mass Spectrom       Date:  2015-02-01       Impact factor: 1.986

3.  Formation of Pyrylium from Aromatic Systems with a Helium:Oxygen Flowing Atmospheric Pressure Afterglow (FAPA) Plasma Source.

Authors:  Sunil P Badal; Tyree D Ratcliff; Yi You; Curt M Breneman; Jacob T Shelley
Journal:  J Am Soc Mass Spectrom       Date:  2017-03-30       Impact factor: 3.109

4.  Glow flow ionization mass spectrometry of small molecules. A comparison of a glow flow ionization source ('GlowFlow') with electrospray ionization and atmospheric pressure chemical ionization.

Authors:  Rhodri N Owen; Stevan Bajic; Steven L Kelly; Michael R Morris; A Gareth Brenton
Journal:  Rapid Commun Mass Spectrom       Date:  2022-08-15       Impact factor: 2.586

5.  Use of Interrupted Helium Flow in the Analysis of Vapor Samples with Flowing Atmospheric-Pressure Afterglow-Mass Spectrometry.

Authors:  Andrew P Storey; Offer M Zeiri; Steven J Ray; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2016-10-18       Impact factor: 3.109

6.  Measurement and visualization of mass transport for the flowing atmospheric pressure afterglow (FAPA) ambient mass-spectrometry source.

Authors:  Kevin P Pfeuffer; Steven J Ray; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2014-05       Impact factor: 3.109

7.  Plasma-Based Ambient Desorption/Ionization Mass Spectrometry for the Analysis of Liquid Crystals Employed in Display Devices.

Authors:  Christopher Kuhlmann; Jacob T Shelley; Carsten Engelhard
Journal:  J Am Soc Mass Spectrom       Date:  2019-08-05       Impact factor: 3.109

8.  A Versatile Integrated Ambient Ionization Source Platform.

Authors:  Wanpeng Ai; Honggang Nie; Shiyao Song; Xiaoyun Liu; Yu Bai; Huwei Liu
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-30       Impact factor: 3.109

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.