Literature DB >> 22125148

Quantification of underivatised amino acids on dry blood spot, plasma, and urine by HPLC-ESI-MS/MS.

Giuseppe Giordano1, Iole Maria Di Gangi, Antonina Gucciardi, Mauro Naturale.   

Abstract

Enzyme deficiencies in amino acid (AA) metabolism affecting the levels of amino acids and their derivatives in physiological fluids may serve as diagnostically significant biomarkers for one or a group of metabolic disorders. Therefore, it is important to monitor a wide range of free amino acids simultaneously and to quantify them. This is time consuming if we use the classical methods and more than ever now that many laboratories have introduced Newborn Screening Programs for the semiquantitative analysis, detection, and quantification of some amino acids needed to be performed in a short time to reduce the rate of false positives.We have modified the stable isotope dilution HPLC-electrospray ionization (ESI)-MS/MS method previously described by Qu et al. (Anal Chem 74: 2034-2040, 2002) for a more rapid, robust, sensitive, and specific detection and quantification of underivatised amino acids. The modified method reduces the time of analysis to 10 min with very good reproducibility of retention times and a better separation of the metabolites and their isomers.The omission of the derivatization step allowed us to achieve some important advantages: fast and simple sample preparation and exclusion of artefacts and interferences. The use of this technique is highly sensitive, specific, and allows monitoring of 40 underivatized amino acids, including the key isomers and quantification of some of them, in order to cover many diagnostically important intermediates of metabolic pathways.We propose this HPLC-ESI-MS/MS method for underivatized amino acids as a support for the Newborn Screening as secondary test using the same dried blood spots for a more accurate and specific examination in case of suspected metabolic diseases. In this way, we avoid plasma collection from the patient as it normally occurs, reducing anxiety for the parents and further costs for analysis.The same method was validated and applied also to plasma and urine samples with good reproducibility, accuracy, and precision. The fast run time, feasibility of high sample throughput, and small amount of sample required make this method very suitable for routine analysis in the clinical setting.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22125148     DOI: 10.1007/978-1-61779-445-2_18

Source DB:  PubMed          Journal:  Methods Mol Biol        ISSN: 1064-3745


  3 in total

1.  High levels of blood glutamic acid and ornithine in children with intellectual disability.

Authors:  Muhammad Wasim; Haq Nawaz Khan; Hina Ayesha; Abdul Tawab; Fazal E Habib; Muhammad Rafique Asi; Mazhar Iqbal; Fazli Rabbi Awan
Journal:  Int J Dev Disabil       Date:  2020-12-21

2.  Dried Blood Spot Methodology in Combination With Liquid Chromatography/Tandem Mass Spectrometry Facilitates the Monitoring of Teriflunomide.

Authors:  Aziz Filali-Ansary; Catherine Lunven; Sandrine Turpault; Yann-Joel Beyer; Amy OʼBrien; Astrid Delfolie; Neli Boyanova; Ger-Jan Sanderink; Francesca Baldinetti
Journal:  Ther Drug Monit       Date:  2016-08       Impact factor: 3.681

3.  Development and validation of an ultra-performance liquid chromatography quadrupole time of flight mass spectrometry method for rapid quantification of free amino acids in human urine.

Authors:  Richard Joyce; Viktorija Kuziene; Xin Zou; Xueting Wang; Frank Pullen; Ruey Leng Loo
Journal:  Amino Acids       Date:  2015-08-29       Impact factor: 3.520

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.