Literature DB >> 22123021

Influence of etching ability of one-step self-etch adhesives on bonding to sound and non-carious cervical sclerotic dentin.

Yi-Ling Tsai1, Masatoshi Nakajima, Chen-Ying Wang, Richard M Foxton, Chun-Pin Lin, Junji Tagami.   

Abstract

The purpose of this study was to evaluate influence of etching ability of one-step self-etch adhesives on bonding to non-carious cervical sclerotic lesion. Forty-eight human maxillary premolars with and without natural non-carious cervical sclerotic lesions at buccal surfaces were used in this study. Artificial wedge-shaped lesions were prepared in sound premolars. All lesions were bonded with Bond Force (BF; pH=2.3) or G-Bond Plus (GBA; pH=1.5) according to the manufacturers' instructions. After water storage for 24 hours at 37°C, bonded specimens were subjected to microtensile bond test to measure bond strength to the gingival wall in each lesion. The μTBS of BF to the natural lesion was significantly lower than that of artificial lesion (p<0.05), while for GBA, there is no significant difference (p>0.05). There was no difference in μTBS to artificial lesion between these two adhesives, however in case of non-carious cervical sclerotic lesion, the μTBS of GBA was statistically higher than that of BF.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22123021     DOI: 10.4012/dmj.2011-111

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  5 in total

1.  Shear bond strength of one-step self-etch adhesives: pH influence.

Authors:  Claudio Poggio; Riccardo Beltrami; Andrea Scribante; Marco Colombo; Marco Chiesa
Journal:  Dent Res J (Isfahan)       Date:  2015 May-Jun

2.  A comparative study of the microtensile bond strength and microstructural differences between sclerotic and Normal dentine after surface pretreatment.

Authors:  Jinhua Wang; Weijian Song; Lei Zhu; Xin Wei
Journal:  BMC Oral Health       Date:  2019-10-07       Impact factor: 2.757

3.  Comparative evaluation of shear bond strength of sixth- and seventh-generation bonding agents with varying pH - An in vitro study.

Authors:  Asim Jamadar; Amulya Vanti; Veerendra Uppin; Madhu Pujar; Sheetal Ghivari; Hemant Vagarali
Journal:  J Conserv Dent       Date:  2020-11-05

4.  Effect of Er,Cr:YSGG Laser at Different Output Powers on the Micromorphology and the Bond Property of Non-Carious Sclerotic Dentin to Resin Composites.

Authors:  Xiang Sun; Jinghao Ban; Xinjia Sha; Weiguo Wang; Yang Jiao; Wanshan Wang; Yanwei Yang; Jingjing Wei; Lijuan Shen; Jihua Chen
Journal:  PLoS One       Date:  2015-11-06       Impact factor: 3.240

Review 5.  The microtensile bond strength test: Its historical background and application to bond testing.

Authors:  Hidehiko Sano; Abu Faem Mohammad Almas Chowdhury; Pipop Saikaew; Mariko Matsumoto; Shuhei Hoshika; Monica Yamauti
Journal:  Jpn Dent Sci Rev       Date:  2019-11-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.