Literature DB >> 22120046

Sources of variation and bias in assessing left ventricular volumes and dyssynchrony using three-dimensional echocardiography.

Denisa Muraru1, Luigi P Badano, Davide Ermacora, Gianluca Piccoli, Sabino Iliceto.   

Abstract

Study aim To explore various sources of variability in the measurement of LV volumes and dyssynchrony by 3D echocardiography (3DE). Methods We studied 100 patients (58 ± 18 years, 51 men) to assess the impact of: (1) manual editing; (2) 3D data set temporal resolution; (3) LV 16- or 17-segmentation model; (4) software sensitivity for automated endocardial surface detection; and (5) image quality, on the measurement of LV end-diastolic (EDV) and end-systolic (ESV) volumes, sphericity indices (EDSI, ESSI), ejection fraction (EF) and dyssynchrony (SDI). Two- and 4-beat LV full-volume data sets were analyzed and compared. Cardiac magnetic resonance (CMR) was used as reference in 26 patients. Results Manual editing of endocardial surface improved the agreement of LV volumes with CMR, but increased SDI (SDI17: 5.6 ± 0.5% vs. 4.3 ± 0.3%; P < 0.0001). Data set temporal resolution had no significant impact on LV parameters. Adding the 17th to 16-segment LV model did not significantly increase SDI. Reducing software sensitivity in endocardial surface detection increased EDV (101 ± 46 ml vs. 118 ± 50 ml) and sphericity, decreased SDI (SDI 17: 6.7 ± 3.3% vs. 2.9 ± 3.7%) (P < 0.05 for all), and improved agreement of EDV and ESV with CMR. Impact of software sensitivity in LV endocardium detection on LV parameters was related to image quality: higher on SDI in pts with suboptimal quality (SDI 17 bias 4.5% vs. 3.2%, P < 0.05); higher on LV volumes in patients with optimal quality (EDV bias 14 ml vs. 19 ml, ESV bias 5 ml vs. 9 ml; P = 0.01). Conclusions Manual editing, software settings and image quality significantly impact on 3D LV volumes and dyssynchrony assessment.

Entities:  

Mesh:

Year:  2011        PMID: 22120046     DOI: 10.1007/s10554-011-9985-0

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  33 in total

Review 1.  Timing of aortic valve surgery.

Authors:  C M Otto
Journal:  Heart       Date:  2000-08       Impact factor: 5.994

Review 2.  Critical appraisal of methods to assess mechanical dyssynchrony.

Authors:  Cheuk-Man Yu; Jeroen J Bax; John Gorcsan
Journal:  Curr Opin Cardiol       Date:  2009-01       Impact factor: 2.161

3.  Echocardiographic assessment of left ventricular dyssynchrony--is three-dimensional echocardiography just the latest kid on the block?

Authors:  Mark Monaghan
Journal:  J Am Soc Echocardiogr       Date:  2009-03       Impact factor: 5.251

Review 4.  Contrast echocardiography: evidence-based recommendations by European Association of Echocardiography.

Authors:  Roxy Senior; Harald Becher; Mark Monaghan; Luciano Agati; Jose Zamorano; Jean Louis Vanoverschelde; Petros Nihoyannopoulos
Journal:  Eur J Echocardiogr       Date:  2009-03

5.  Validation of a novel automated border-detection algorithm for rapid and accurate quantitation of left ventricular volumes based on three-dimensional echocardiography.

Authors:  Denisa Muraru; Luigi P Badano; Gianluca Piccoli; Pasquale Gianfagna; Lorenzo Del Mestre; Davide Ermacora; Alessandro Proclemer
Journal:  Eur J Echocardiogr       Date:  2009-12-30

6.  Can real-time three-dimensional echocardiography be used reliably for the assessment of left ventricular dyssynchrony?

Authors:  Richa Agarwal; John F Beshai; Roberto M Lang
Journal:  Arch Cardiovasc Dis       Date:  2009-07-04       Impact factor: 2.340

7.  Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction.

Authors:  Carly Jenkins; Kristen Bricknell; Jonathan Chan; Lizelle Hanekom; Thomas H Marwick
Journal:  Am J Cardiol       Date:  2006-12-01       Impact factor: 2.778

8.  Natural history of asymptomatic left ventricular systolic dysfunction in the community.

Authors:  Thomas J Wang; Jane C Evans; Emelia J Benjamin; Daniel Levy; Elizabeth C LeRoy; Ramachandran S Vasan
Journal:  Circulation       Date:  2003-08-11       Impact factor: 29.690

9.  Baseline and follow-up assessment of regional left ventricular volume using 3-Dimensional echocardiography: comparison with cardiac magnetic resonance.

Authors:  Carly Jenkins; Thomas H Marwick
Journal:  Cardiovasc Ultrasound       Date:  2009-11-19       Impact factor: 2.062

10.  Real-time three-dimensional echocardiography permits quantification of left ventricular mechanical dyssynchrony and predicts acute response to cardiac resynchronization therapy.

Authors:  Nina Ajmone Marsan; Gabe B Bleeker; Claudia Ypenburg; Stefano Ghio; Nico R van de Veire; Eduard R Holman; Ernst E van der Wall; L Tavazzi; Martin J Schalij; Jeroen J Bax
Journal:  J Cardiovasc Electrophysiol       Date:  2007-12-20
View more
  9 in total

1.  Real-time three-dimensional left ventricular contraction in patients with diastolic dysfunction.

Authors:  Suzan Hatipoğlu; Gamze Babur Güler; Özgür Kaya; Gökhan Kahveci; Ekrem Güler; Elif Eroğlu; Nihal Özdemir
Journal:  J Med Ultrason (2001)       Date:  2016-04-06       Impact factor: 1.314

2.  Current clinical applications of transthoracic three-dimensional echocardiography.

Authors:  Luigi P Badano; Francesca Boccalini; Denisa Muraru; Lucia Dal Bianco; Diletta Peluso; Roberto Bellu; Giacomo Zoppellaro; Sabino Iliceto
Journal:  J Cardiovasc Ultrasound       Date:  2012-03-27

3.  Three-Dimensional Echocardiographic Automated Quantification of Left Heart Chamber Volumes Using an Adaptive Analytics Algorithm: Feasibility and Impact of Image Quality in Nonselected Patients.

Authors:  Diego Medvedofsky; Victor Mor-Avi; Isida Byku; Amita Singh; Lynn Weinert; Megan Yamat; Eric Kruse; Boguslawa Ciszek; Alma Nelson; Kyoko Otani; Masaaki Takeuchi; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2017-07-06       Impact factor: 5.251

4.  Functional and Metabolic Imaging in Heart Failure with Preserved Ejection Fraction: Promises, Challenges, and Clinical Utility.

Authors:  Matthew K Burrage; Andrew J Lewis; Jack J J Miller
Journal:  Cardiovasc Drugs Ther       Date:  2022-07-26       Impact factor: 3.947

5.  Three-dimensional echocardiographic assessment of left ventricular volume in different heart diseases using a fully automated quantification software.

Authors:  Chen-Ke Pan; Bo-Wen Zhao; Xuan-Xuan Zhang; Mei Pan; Yan-Kai Mao; Yuan Yang
Journal:  World J Clin Cases       Date:  2022-05-06       Impact factor: 1.534

Review 6.  The clinical benefits of adding a third dimension to assess the left ventricle with echocardiography.

Authors:  Luigi P Badano
Journal:  Scientifica (Cairo)       Date:  2014-05-15

7.  Heart Model A.I. Three-Dimensional Echocardiographic Evaluation of Left Ventricular Function and Parameter Setting.

Authors:  Yuan-Yuan Xing; Hong-Yuan Xue; Yu-Quan Ye
Journal:  Int J Gen Med       Date:  2021-11-09

8.  Left Heart Chamber Volumetric Assessment by Automated Three-Dimensional Echocardiography in Heart Transplant Recipients.

Authors:  Yiwei Zhang; Chun Wu; Wei Sun; Shuangshuang Zhu; Yanting Zhang; Yuji Xie; Ye Zhu; Zisang Zhang; Yang Zhao; Yuman Li; Mingxing Xie; Li Zhang
Journal:  Front Cardiovasc Med       Date:  2022-04-27

9.  Automated left heart chamber volumetric assessment using three-dimensional echocardiography in Chinese adolescents.

Authors:  Xiu-Xia Luo; Fang Fang; Hung-Kwan So; Chao Liu; Man-Ching Yam; Alex Pui-Wai Lee
Journal:  Echo Res Pract       Date:  2017-09-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.