Susan A Odom1, Aaron C Jackson, Alex M Prokup, Sarut Chayanupatkul, Nancy R Sottos, Scott R White, Jeffrey S Moore.
Abstract
We report a new core-shell microcapsule system for the visual detection of mechanical damage. The core material, 1,3,5,7-cyclooctatetraene, is a conjugated cyclic olefin and a precursor to intensely colored polyacetylene. A combination of poly(urea-formaldehyde) and polyurethane is required to effectively encapsulate the volatile core material. Increasing the outer shell wall thickness and including a core-side prepolymer improves the thermal stability and free-flowing nature of these capsules, which tend to leach and rupture with thinner shell walls. Capsules ruptured in the presence of the Grubbs-Love ruthenium catalyst show immediate color change from nearly colorless to red-orange and dark purple over time, and color change in thin films resulted from scratch damage.Entities:
Year: 2011 PMID: 22114767 DOI: 10.1021/am201048a
Source DB: PubMed Journal: ACS Appl Mater Interfaces ISSN: 1944-8244 Impact factor: 9.229