Literature DB >> 22113980

Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip.

Yuan Z Zhang1, Bin Chen, Sheng Lu, Yong Yang, Jian M Zhao, Rui Liu, Yan B Li, Guo X Pei.   

Abstract

BACKGROUND: The considerable variation in anatomical abnormalities of hip joints associated with different types of developmental dysplasia of hip (DDH) makes reconstruction in total hip arthroplasty (THA) difficult. It is desirable to create patient-specific designs for THA procedures. In the cases of adult single DDH, an accuracy-improved method has been developed for acetabular cup prosthesis implantation of hip arthroplasty.
METHODS: From October 2007 to November 2008, 22 patients with single DDH (according to the Crowe standard, all dysplasia hips were classified as type I) were scanned with spiral CT pre-operatively. These patients scheduled for THA were randomly assigned to undergo either conventional THA (control group, n = 11) or navigation template implantation (NT group, n = 11). In the NT group, three-dimensional (3D) CT pelvis image data were transferred to a computer workstation and 3D models of the hip were reconstructed using the Mimics software. The 3D models were then processed by the Imageware software. In brief, a template that best fitted the location and shape of the acetabular cup was 'reversely' built from the 3D model, the rotation centre of the pathological hip determined by mirroring that of the healthy site, and a guiding hole in the template was then designed. The navigational templates were manufactured using a rapid prototyping machine. These navigation templates guide acetabular component placement.
RESULTS: Based on the predetermined abduction angle 45° and anteversion angle 18°, after 1 year follow-up, the NT group showed significantly smaller differences (1.6° ± 0.4°, 1.9° ± 1.1°) from the predetermined angles than those in the control group (5.8° ± 2.9°, 3.9° ± 2.5°) (P < 0.05).
CONCLUSIONS: The template designs facilitated accurate placement of acetabular components in dysplasia of acetabulum. The hip's center of rotation in DDH could be established using computer-aided design, which provides a useful method for the accurate location of prosthesis with a low cost-performance ratio without excessive technical workload on the surgical team.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2011        PMID: 22113980     DOI: 10.1002/rcs.423

Source DB:  PubMed          Journal:  Int J Med Robot        ISSN: 1478-5951            Impact factor:   2.547


  21 in total

1.  Application of computer-aided design and 3D-printed navigation template in Locking Compression Pediatric Hip PlateΤΜ placement for pediatric hip disease.

Authors:  Pengfei Zheng; Qingqiang Yao; Peng Xu; Liming Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-11       Impact factor: 2.924

2.  Alignment of the lower extremity mechanical axis by computer-aided design and application in total knee arthroplasty.

Authors:  Yuan Z Zhang; Sheng Lu; Hui Q Zhang; Zhong M Jin; Jian M Zhao; Jian Huang; Zhi F Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-26       Impact factor: 2.924

3.  3D Printing Navigation Template Used in Total Hip Arthroplasty for Developmental Dysplasia of the Hip.

Authors:  Liang Yan; Peng Wang; Haibin Zhou
Journal:  Indian J Orthop       Date:  2020-03-30       Impact factor: 1.251

4.  3D-Printed Models versus CT Scan and X-Rays Imaging in the Diagnostic Evaluation of Proximal Humerus Fractures: A Triple-Blind Interobserver Reliability Comparison Study.

Authors:  Gianluca Puglisi; Marco Montemagno; Regina Denaro; Giuseppe Condorelli; Vincenzo Fabrizio Caruso; Andrea Vescio; Gianluca Testa; Vito Pavone
Journal:  Adv Orthop       Date:  2022-06-13

5.  Medical 3D Printing Cost-Savings in Orthopedic and Maxillofacial Surgery: Cost Analysis of Operating Room Time Saved with 3D Printed Anatomic Models and Surgical Guides.

Authors:  David H Ballard; Patrick Mills; Richard Duszak; Jeffery A Weisman; Frank J Rybicki; Pamela K Woodard
Journal:  Acad Radiol       Date:  2019-09-18       Impact factor: 3.173

6.  The ratio of femoral head diameter to pelvic height in the normal hips of a Chinese population.

Authors:  Yanbo Zhang; Jinlan Jiang; Chenyu Wang; Jianlin Zuo; Modi Yang; Jincheng Wang
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-08-27

Review 7.  Computer-assisted orthopaedic surgery and robotic surgery in total hip arthroplasty.

Authors:  Nobuhiko Sugano
Journal:  Clin Orthop Surg       Date:  2013-02-20

Review 8.  The current and possible future role of 3D modelling within oesophagogastric surgery: a scoping review.

Authors:  Henry Robb; Gemma Scrimgeour; Piers Boshier; Anna Przedlacka; Svetlana Balyasnikova; Gina Brown; Fernando Bello; Christos Kontovounisios
Journal:  Surg Endosc       Date:  2022-03-11       Impact factor: 3.453

9.  Computer-Assisted Planning and Patient-Specific Instruments for Bone Tumor Resection within the Pelvis: A Series of 11 Patients.

Authors:  François Gouin; Laurent Paul; Guillaume Anthony Odri; Olivier Cartiaux
Journal:  Sarcoma       Date:  2014-07-02

10.  A semi-automatic computer-aided method for surgical template design.

Authors:  Xiaojun Chen; Lu Xu; Yue Yang; Jan Egger
Journal:  Sci Rep       Date:  2016-02-04       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.