Dialysate saving by automated control of flow rates: comparison between individualized online hemodiafiltration and standard hemodialysis.

Enisa Mesic1, Andreas Bock, Lajos Major, Lajos Vaslaki, Klara Berta, Bjorn Wikstrom, Bernard Canaud, Ralf Wojke.   

Abstract

Cost reduction and quality improvement seem to be conflicting issues. However, online hemodiafiltration (oHDF) with new automatic functions offers a cost-efficient therapy compared to hemodialysis (HD). Seven dialysis centers conducted a randomized clinical trial with cross-over design: high-flux HD vs. postdilutional oHDF with functions coupling both dialysate and substitution flow rates to blood flow rates. During the 6 weeks of the study, all treatment parameters remained unchanged for HD and oHDF, apart from dialysate and substitution flow rate. Treatment data were recorded during each treatment, and predialytic and postdialytic concentrations of urea were recorded at the end of each study phase. The analysis involved 956 treatments of 54 patients. The mean dialysate consumption was 123.2 ± 6.4 l for HD and 113.4 ± 14.9 l for oHDF (p < 0.0001), the mean dialysis dose was 1.42 ± 0.23 for HD and 1.47 ± 0.26 for oHDF (p < 0.0001); oHDF resulted in a lower dialysate consumption (8.0% less) and a slightly increased dialysis dose (Kt/V 3.5% higher) compared to HD. oHDF with the investigated automatic functions offers substantial savings in dialysate consumption without decreasing dialysis dose.
© 2011 The Authors; Hemodialysis International © 2011 International Society for Hemodialysis.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22111821     DOI: 10.1111/j.1542-4758.2011.00577.x

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  3 in total

1.  Haemodialysis therapy and sustainable growth: a corporate experience in France.

Authors:  Georges Bendine; Fabien Autin; Bruno Fabre; Olivier Bardin; François Rabasco; Jean-Marc Cabanel; Charles Chazot
Journal:  Nephrol Dial Transplant       Date:  2020-12-04       Impact factor: 5.992

Review 2.  Advanced hemodialysis equipment for more eco-friendly dialysis.

Authors:  Adelheid Gauly; Nicole Fleck; Fatih Kircelli
Journal:  Int Urol Nephrol       Date:  2021-09-04       Impact factor: 2.370

3.  Green nephrology and eco-dialysis: a position statement by the Italian Society of Nephrology.

Authors:  Giorgina Barbara Piccoli; Adamasco Cupisti; Filippo Aucella; Giuseppe Regolisti; Carlo Lomonte; Martina Ferraresi; D'Alessandro Claudia; Carlo Ferraresi; Roberto Russo; Vincenzo La Milia; Bianca Covella; Luigi Rossi; Antoine Chatrenet; Gianfranca Cabiddu; Giuliano Brunori
Journal:  J Nephrol       Date:  2020-04-15       Impact factor: 3.902