Literature DB >> 22111758

Impact of implant diameter on bone level changes around platform switched implants: preliminary results of 18 months follow-up a prospective randomized match-paired controlled trial.

Luigi Canullo1, Giuliano Iannello, Miguel Peñarocha, Berta Garcia.   

Abstract

OBJECTIVE: This prospective randomized match-paired controlled trial aimed to evaluate the impact of implant platform diameter on marginal bone level around implants restored according to the platform switching (PS) concept.
MATERIAL AND METHODS: A total of 24 implants were examined in 12 patients. All patients received two adjacent implants inserted at the crestal level: 4.3 mm (control group) and 4.8 mm (test group) in diameter. Mesio-distal implant position was randomly performed. According to the PS concept, for restoration, a 3.8 and 4.3 mm diameter abutment was used, respectively in the control and test groups, resulting, in both groups, with 0.25 mm of implant/abutment mismatching. Implant restorations were splinted. Eighteen months after final restoration, periapical standardized digital radiographs were taken to evaluate marginal bone level alterations after loading. The Wilcoxon Signed-Rank Test was selected to identify differences between groups.
RESULTS: At the last follow-up, control implants exhibited a mean bone loss value of 1.10 mm (SD: 0.47 mm); the test group showed a mean value of 1.09 mm (SD: 0.08 mm). No statistically significant differences were found between test and control groups.
CONCLUSIONS: Within the limits of this study, the present results suggest that bone resorption is mostly related to biologic (biologic width re-establishment) rather than to biomechanical factors (implant platform diameter). Furthermore long-term studies with a wider sample size are needed to confirm the platform diameter influence on hard tissue response around implants restored according to the PS concept.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22111758     DOI: 10.1111/j.1600-0501.2011.02297.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  7 in total

Review 1.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

2.  Marginal bone response of implants with platform switching and non-platform switching abutments in posterior healed sites: a 1-year prospective study.

Authors:  Yun-Chi Wang; Joseph Y K Kan; Kitichai Rungcharassaeng; Phillip Roe; Jaime L Lozada
Journal:  Clin Oral Implants Res       Date:  2014-01-03       Impact factor: 5.977

3.  Radiographic evaluation of conical tapered platform-switched implants in the posterior mandible: 1-year results of a two-center prospective study.

Authors:  Maximilian Moergel; Salomão Rocha; Ana Messias; Pedro Nicolau; Fernando Guerra; Wilfried Wagner
Journal:  Clin Oral Implants Res       Date:  2015-06-21       Impact factor: 5.977

4.  Current results and trends in platform switching.

Authors:  Hadi Salimi; Omid Savabi; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2011-12

5.  Platform switch versus platform match in the posterior mandible – 1-year results of a multicentre randomized clinical trial.

Authors:  Fernando Guerra; Wilfried Wagner; Jörg Wiltfang; Salomão Rocha; Maximilian Moergel; Eleonore Behrens; Pedro Nicolau
Journal:  J Clin Periodontol       Date:  2014-05       Impact factor: 8.728

6.  Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical trial.

Authors:  Salomão Rocha; Wilfried Wagner; Jörg Wiltfang; Pedro Nicolau; Maximilian Moergel; Ana Messias; Eleonore Behrens; Fernando Guerra
Journal:  J Clin Periodontol       Date:  2016-03-30       Impact factor: 8.728

7.  Implant-prosthetic rehabilitation of patients with severe horizontal bone deficit on mini-implants with two-piece design-retrospective analysis after a mean follow-up of 5 years.

Authors:  Lukas Wimmer; Pantelis Petrakakis; Karim El-Mahdy; Surian Herrmann; Dirk Nolte
Journal:  Int J Implant Dent       Date:  2021-07-28
  7 in total