Literature DB >> 22109957

Transcatheter aortic valve implantation with a self-expanding nitinol bioprosthesis: prediction of the need for permanent pacemaker using simple baseline and procedural characteristics.

Francesco Saia1, Pedro A Lemos, Barbara Bordoni, Elena Cervi, Giuseppe Boriani, Cristina Ciuca, Nevio Taglieri, Jose Mariani, Roberto Kalil Filho, Antonio Marzocchi.   

Abstract

OBJECTIVE: To ascertain incidence and predictors of new permanent pacemaker (PPM) following transcatheter aortic valve implantation (TAVI) with the self-expanding aortic bioprosthesis.
BACKGROUND: TAVI with the Medtronic Corevalve (MCV) Revalving System (Medtronic, Minneapolis, MN) has been associated with important post-procedural conduction abnormalities and frequent need for PPM.
METHODS: Overall, 73 consecutive patients with severe symptomatic AS underwent TAVI with the MCV at two institutions; 10 patients with previous pacemaker and 3 patients with previous aortic valve replacement were excluded for this analysis. Clinical, echocardiographic, and procedural data were collected prospectively in a dedicated database. A standard 12-lead ECG was recorded in all patients at baseline, after the procedure and predischarge. Decision to implant PPM was taken according to current guidelines. Logistic multivariable modeling was applied to identify independent predictors of PPM at discharge.
RESULTS: Patients exhibited high-risk features as evidenced by advanced age (mean = 82.1 ± 6.2 years) and high surgical scores (logistic EuroSCORE 23.0 ± 12.8%, STS score 9.4 ± 6.9%). The incidence of new PPM was 28.3%. Interventricular septum thickness and logistic Euroscore were the baseline independent predictors of PPM. When procedural variables were included, the independent predictors of PPM were interventricular septum thickness (OR 0.52; 95% CI 0.32-0.85) and the distance between noncoronary cusp and the distal edge of the prosthesis (OR 1.37; 95% CI 1.03-1.83).
CONCLUSIONS: Conduction abnormalities are frequently observed after TAVI with self-expandable bioprosthesis and definitive pacing is required in about a third of the patients, with a clear association with depth of implant and small interventricular septum thickness.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22109957     DOI: 10.1002/ccd.23336

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  9 in total

Review 1.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

Review 2.  Clinical significance of conduction disturbances after aortic valve intervention: current evidence.

Authors:  Manuel Martinez-Selles; Peter Bramlage; Martin Thoenes; Gerhard Schymik
Journal:  Clin Res Cardiol       Date:  2014-07-04       Impact factor: 5.460

Review 3.  Transcatheter aortic valve implantation-induced left bundle branch block: causes and consequences.

Authors:  Thomas T Poels; Patrick Houthuizen; Leen A F M Van Garsse; Jos G Maessen; Peter de Jaegere; Frits W Prinzen
Journal:  J Cardiovasc Transl Res       Date:  2014-05-07       Impact factor: 4.132

Review 4.  New conduction abnormalities after TAVI--frequency and causes.

Authors:  Robert M van der Boon; Rutger-Jan Nuis; Nicolas M Van Mieghem; Luc Jordaens; Josep Rodés-Cabau; Ron T van Domburg; Patrick W Serruys; Robert H Anderson; Peter P T de Jaegere
Journal:  Nat Rev Cardiol       Date:  2012-05-01       Impact factor: 32.419

Review 5.  Echocardiographic imaging of procedural complications during balloon-expandable transcatheter aortic valve replacement.

Authors:  Rebecca T Hahn; Susheel Kodali; E Murat Tuzcu; Martin B Leon; Samir Kapadia; Deepika Gopal; Stamatios Lerakis; Brian R Lindman; Zuyue Wang; John Webb; Vinod H Thourani; Pamela S Douglas
Journal:  JACC Cardiovasc Imaging       Date:  2015-03

Review 6.  Transcatheter aortic valve implantation.

Authors:  Thomas M Snow; Neil Moat; Sarah Barker; Alison Duncan; Carlo Di Mario
Journal:  Glob Cardiol Sci Pract       Date:  2012-08-30

7.  Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.

Authors:  Lennart van Gils; Didier Tchetche; Thibault Lhermusier; Masieh Abawi; Nicolas Dumonteil; Ramón Rodriguez Olivares; Javier Molina-Martin de Nicolas; Pieter R Stella; Didier Carrié; Peter P De Jaegere; Nicolas M Van Mieghem
Journal:  J Am Heart Assoc       Date:  2017-03-03       Impact factor: 5.501

Review 8.  Conduction abnormalities after transcatheter aortic valve implantation.

Authors:  Panagiotis Karyofillis; Anna Kostopoulou; Sofia Thomopoulou; Martha Habibi; Efthimios Livanis; George Karavolias; Vassilis Voudris
Journal:  J Geriatr Cardiol       Date:  2018-01       Impact factor: 3.327

Review 9.  Conduction disturbances after transcatheter aortic valve implantation procedures - predictors and management.

Authors:  Krzysztof Wilczek; Rafał Reguła; Kamil Bujak; Piotr Chodór; Michał Długaszek; Mariusz Gąsior
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-08-19       Impact factor: 1.426

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.