Literature DB >> 22109190

Calibration-free wavelength modulated TDLAS under high absorbance conditions.

Peng Zhimin1, Ding Yanjun, Che Lu, Li Xiaohang, Zheng Kangjie.   

Abstract

Currently, the method that uses a first-order Taylor series to approximate laser transmission has seriously affected the gas concentration measurement accuracy of tunable diode laser-absorption spectroscopy (TDLAS). This paper employs a second-order Taylor series to approximate laser transmission, and a high-precision second-order algorithm has been established that can determine the gas concentration directly. Then, this algorithm is used to test the NH₃ mole fraction in a cell with NH₃-Air mixtures. Experimental results show that the second-order algorithm not only effectively improves the measurement accuracy of gas concentration but also greatly broadens the scope of TDLAS.

Year:  2011        PMID: 22109190     DOI: 10.1364/OE.19.023104

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  1 in total

1.  Highly Sensitive, Calibration-Free WM-DAS Method for Recovering Absorbance-Part I: Theoretical Analysis.

Authors:  Zhimin Peng; Yanjun Du; Yanjun Ding
Journal:  Sensors (Basel)       Date:  2020-01-26       Impact factor: 3.576