Literature DB >> 22108354

Comparison of aphakic refraction formulas for secondary in-the-bag intraocular lens power estimation in children.

Ghada Abdel-Hafez1, Rupal H Trivedi, M Edward Wilson, Dipankar Bandyopadhyay.   

Abstract

PURPOSE: Intraocular lens (IOL) formulas based on aphakic refraction alone have been proposed as an alternative to biometry-based formulas. The purpose of this study was to determine the relative accuracy of these simplified formulas.
METHODS: Records of patients who received secondary in-the-bag (IOL) implants and for whom aphakic refraction was obtainable were retrospectively studied. The formulas for IOL power calculation by Hug (J Pediatr Ophthalmol Strabismus 2004;41;209-11) and Khan and by AlGaeed (Br J Ophthalmol 2006;90:1458-60; modified to account for greater K values in our population) were compared with the biometry-based Holladay 1 formula by calculating the absolute prediction error for each.
RESULTS: Twenty eyes met the inclusion criteria. The average age at IOL implantation was 4.8 ± 3.4 years. The mean of the absolute value of the prediction error when we used the Hug's formula was 2.4 ± 2.1 D; with Khan's formula, 2.4 ± 2.0 D; and with biometry, 1.6 ± 1.4 D. None of these differences was statistically significant (paired t test: Hug vs Khan, P = 0.9; biometry vs Hug, P = 0.3; biometry vs Khan, P = 0.2). The absolute prediction error was more than 2 D in 8 of 20 eyes (40%) when we used Hug's formula, 11 of 20 eyes (55%) with Khan's formula, and 5 of 20 eyes (25%) with biometry.
CONCLUSIONS: Although the 0.8 D reduction in accuracy of the refraction-based formulas was not statistically significant, we recommend continued use of biometry-based formulas for IOL power calculation. Aphakic refraction may be used to confirm IOL power prediction when biometry is difficult.
Copyright © 2011 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22108354     DOI: 10.1016/j.jaapos.2011.05.021

Source DB:  PubMed          Journal:  J AAPOS        ISSN: 1091-8531            Impact factor:   1.220


  4 in total

1.  Axial length measurement techniques in pediatric eyes with cataract.

Authors:  M Edward Wilson; Rupal H Trivedi
Journal:  Saudi J Ophthalmol       Date:  2012-01

Review 2.  Pediatric cataract: challenges and future directions.

Authors:  Anagha Medsinge; Ken K Nischal
Journal:  Clin Ophthalmol       Date:  2015-01-07

3.  Accuracy of formulae for secondary intraocular lens power calculations in pediatric aphakia.

Authors:  Fouad R Nakhli; Khaled Emarah; Laila Jeddawi
Journal:  J Curr Ophthalmol       Date:  2017-06-13

Review 4.  Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes?

Authors:  Savleen Kaur; Jaspreet Sukhija; Jagat Ram
Journal:  Indian J Ophthalmol       Date:  2021-12       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.