Literature DB >> 22108101

Vertical discrepancy and microleakage of laser-sintered and vacuum-cast implant-supported structures luted with different cement types.

Raquel Castillo Oyagüe1, Andrés Sánchez-Turrión, José Francisco López-Lozano, M Jesús Suárez-García.   

Abstract

OBJECTIVES: This study aimed to evaluate the vertical misfit and microleakage of laser-sintered and vacuum-cast cement-retained implant-supported frameworks.
METHODS: Three-unit implant-fixed structures were constructed with: (1) laser-sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC); and (3) vacuum-cast Pd-Au (CP). Every framework was luted onto 2 prefabricated abutments under constant seating pressure. Each alloy group was randomly divided into three subgroups (n=10) according to the cement used: (1) Ketac Cem Plus (KC); (2) Panavia F 2.0 (PF); and (3) RelyX Unicem 2 Automix (RXU). After 30 days of water ageing, vertical discrepancy was measured by SEM, and marginal microleakage was scored using a digital microscope. Three-way ANOVA and Student-Newman-Keuls tests were run to investigate the effect of alloy/fabrication technique, FDP retainer, and cement type on vertical misfit. Data for marginal microleakage were analysed with Kruskal-Wallis and Dunn's tests (α=0.05).
RESULTS: Vertical discrepancy was affected by alloy/manufacturing technique and cement type (p<0.001). Despite the luting agent, LS structures showed the best marginal adaptation, followed by CP, and CC. Within each alloy group, KC provided the best fit, whilst the use of PF or RXU resulted in no significant differences. Regardless of the framework alloy, KC exhibited the highest microleakage scores, whilst PF and RXU showed values that were comparable to each other.
CONCLUSIONS: Laser-sintered Co-Cr structures achieved the best fit in the study. Notwithstanding the framework alloy, resin-modified glass-ionomer demonstrated better marginal fit but greater microleakage than did MDP-based and self-adhesive dual-cure resin cements. All groups were within the clinically acceptable misfit range. CLINICAL SIGNIFICANCE: Laser-sintered Co-Cr may be an alternative to cast base metal and noble alloys to obtain passive-fitting structures. Despite showing higher discrepancies, resin cements displayed lower microleakage than resin-modified glass-ionomer. Further research is necessary to determine whether low microleakage scores may guarantee a suitable seal that could compensate for misfit.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22108101     DOI: 10.1016/j.jdent.2011.11.007

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  8 in total

1.  Evaluation and comparison of the marginal adaptation of two different substructure materials.

Authors:  Tahir Karaman; Sabiha Zelal Ulku; Ali Ihsan Zengingul; Sedat Guven; Veysel Eratilla; Ebru Sumer
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

2.  Correlation between Microleakage and Absolute Marginal Discrepancy in Zirconia Crowns Cemented with Four Resin Luting Cements: An In Vitro Study.

Authors:  Abad-Coronel Cristian; Li Jeanette; Martínez-Rus Francisco; Pradíes Guillermo
Journal:  Int J Dent       Date:  2016-09-18

3.  Reliability of new poly (lactic-co-glycolic acid) membranes treated with oxygen plasma plus silicon dioxide layers for pre-prosthetic guided bone regeneration processes.

Authors:  G Castillo-Dalí; R Castillo-Oyagüe; A Batista-Cruzado; C López-Santos; A Rodríguez-González-Elipe; J-L Saffar; C-D Lynch; J-L Gutiérrez-Pérez; D Torres-Lagares
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-03-01

4.  Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials.

Authors:  Vahideh Nazari; Safoura Ghodsi; Marzieh Alikhasi; Majid Sahebi; Ahmad Reza Shamshiri
Journal:  J Dent (Tehran)       Date:  2016-11

5.  Marginal Discrepancy of Single Implant-Supported Metal Copings Fabricated by Various CAD/CAM and Conventional Techniques Using Different Materials.

Authors:  Safoura Ghodsi; Marzieh Alikhasi; Nika Soltani
Journal:  Eur J Dent       Date:  2019-11-26

6.  In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns.

Authors:  Aristeidis A Villias; Stefanos G Kourtis; Hercules C Karkazis; Gregory L Polyzois
Journal:  Int J Implant Dent       Date:  2021-02-15

7.  Comparative evaluation of microleakage of metallic copings luted with three different commercially available luting cements: An in vitro study.

Authors:  Mohit Handa; Pratibha Marya; Varun Gupta; Sumit Chopra
Journal:  J Indian Prosthodont Soc       Date:  2021 Jan-Mar

8.  Microleakage at Implant Abutment and Prosthesis Interface in Cemented Implant-Supported Prosthesis.

Authors:  Soni Kumari; Manish Shivaji Jadhav; Vishal Gupta; Tarun Koshy Isaac; Angel Subramanium; Vinit Kumar
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.