Literature DB >> 22104688

Choosing an appropriate length of loop type ureteral stent using direct ureteral length measurement.

Takashi Kawahara1, Hiroki Ito, Hideyuki Terao, Minoru Yoshida, Takehiko Ogawa, Hiroji Uemura, Yoshinobu Kubota, Junichi Matsuzaki.   

Abstract

PURPOSE: The ureteral stent is now a fundamental part of many urological procedures. To decrease ureteral stent-related symptoms, loop type ureteral stent was developed. However the most important factor to decrease urinary symptoms is choosing the optimal length of a ureteral stent. We investigated the relationship between the actual ureteral length and the loop type ureteral stent position.
MATERIALS AND METHODS: A total of 226 loop type polyurethane ureteral stents (156 patients) were inserted with four options for stent length (20, 22, 24 and 26 cm). The ureteral length was measured using a ruled 5-Fr ureteral catheter. The appropriateness of stent position was defined into three groups based on kidney-ureter-bladder films.
RESULTS: Nine stents (3.9%) migrated, 171 stents (75.7%) were in the appropriate position and 46 stents (19.5%) were overlong. The rate of migration rate and overlong stents closely correlated with the ureteral length when the proximal end of the stent was in the renal pelvis.
CONCLUSIONS: It is appropriate to choose a loop type ureteral stent that is the same or 1 cm less than the length of the ureter when the proximal end of the stent will be in the renal pelvis.
Copyright © 2011 S. Karger AG, Basel.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22104688     DOI: 10.1159/000332431

Source DB:  PubMed          Journal:  Urol Int        ISSN: 0042-1138            Impact factor:   2.089


  5 in total

1.  Changing to a loop-type ureteral stent decreases patients' stent-related symptoms.

Authors:  Takashi Kawahara; Hiroki Ito; Hideyuki Terao; Takehiko Ogawa; Hiroji Uemura; Yoshinobu Kubota; Junichi Matsuzaki
Journal:  Urol Res       Date:  2012-08-17

2.  Encrusted Ureteral Stent Retrieval Using Flexible Ureteroscopy with a Ho: YAG Laser.

Authors:  Takashi Kawahara; Hiroki Ito; Hideyuki Terao; Takehiko Ogawa; Hiroji Uemura; Yoshinobu Kubota; Junichi Matsuzaki
Journal:  Case Rep Med       Date:  2012-04-03

3.  Discolored ureteral stents: findings in urinalysis and urine culture.

Authors:  Takashi Kawahara; Hiroshi Miyamoto; Hiroki Ito; Hideyuki Terao; Hiroji Uemura; Yoshinobu Kubota; Junichi Matsuzaki
Journal:  PLoS One       Date:  2015-04-07       Impact factor: 3.240

4.  Developing a preoperative predictive model for ureteral length for ureteral stent insertion.

Authors:  Takashi Kawahara; Kentaro Sakamaki; Hiroki Ito; Shinnosuke Kuroda; Hideyuki Terao; Kazuhide Makiyama; Hiroji Uemura; Masahiro Yao; Hiroshi Miyamoto; Junichi Matsuzaki
Journal:  BMC Urol       Date:  2016-11-30       Impact factor: 2.264

5.  Double J stent migration as renal penetration.

Authors:  Takashi Ando; Akira Kazama
Journal:  Urol Case Rep       Date:  2021-06-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.