Literature DB >> 22099659

Novel CeO₂-based screen-printed potentiometric electrodes for pH monitoring.

S Betelu1, K Polychronopoulou, C Rebholz, I Ignatiadis.   

Abstract

Nuclear waste repositories are being installed in deep excavated rock formations in some places in Europe to isolate and store radioactive waste. In France, the Callovo-Oxfordian formation (COx) is a possible candidate for nuclear waste storage. This work investigates the applicability of CeO(2)-based oxides (CeO(2), Ce(0.8)Sm(0.2)O(2) and Ce(0.8)Zr(0.2)O(2)) for monitoring the pH of the COx pore water (T=25°C). The study is limited to the pH range between 5.5 and 13.2, which includes the pH values that have been encountered or are anticipated in the COx formation during its evolution as radioactive waste repository due mainly to alkalinisation, an increase in salinity, and a decrease in redox potential. Screen-printing was done to assemble electrodes and rapidly generate data sets. The electrochemical behavior of CeO(2)-based screen-printed electrodes (CeO(2)-based SPEs) was determined by cyclic voltammetry and electrochemical impedance spectroscopy. The use of the electrodes for pH sensing was then evaluated by potentiometric measurements. The feasibility of measuring pH with CeO(2)-based SPEs was first tested in NH(4)Cl/NH(3) buffer solutions, leading to electrode calibration over the widest range of pH, from around neutral to basic pH. Experiments were then conducted in NaHCO(3)/Na(2)CO(3) buffer samples similar to conditions prevailing in the COx formation. Ce(0.8)Zr(0.2)O(2) SPEs exhibit a near-Nernstian behavior (sensitivity -(51±2)mV/pH) in the pH range of 5.5-13.2 at 25°C. Electrode response was slightly affected by the direction of the pH change. Electrode reliability was clearly demonstrated for pH monitoring. Probes based on the same components, but more durably designed, could be considered for pH measurements in radioactive waste repositories.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22099659     DOI: 10.1016/j.talanta.2011.09.051

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Molecular Wiring in Smart Dressings: Opening a New Route to Monitoring Wound pH.

Authors:  Anna McLister; James Davis
Journal:  Healthcare (Basel)       Date:  2015-06-25

2.  A Multi-Parametric Device with Innovative Solid Electrodes for Long-Term Monitoring of pH, Redox-Potential and Conductivity in a Nuclear Waste Repository.

Authors:  Jordan Daoudi; Stephanie Betelu; Theodore Tzedakis; Johan Bertrand; Ioannis Ignatiadis
Journal:  Sensors (Basel)       Date:  2017-06-13       Impact factor: 3.576

3.  Hydrous Cerium Dioxide-Based Materials as Solid-Contact Layers in Potassium-Selective Electrodes.

Authors:  Nikola Lenar; Robert Piech; Beata Paczosa-Bator
Journal:  Membranes (Basel)       Date:  2022-03-22

Review 4.  Disposable screen printed electrochemical sensors: tools for environmental monitoring.

Authors:  Akhtar Hayat; Jean Louis Marty
Journal:  Sensors (Basel)       Date:  2014-06-13       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.