| Literature DB >> 22099073 |
Matthew K Mian1, Brian V Nahed, Brian P Walcott, Jean-Valery Coumans.
Abstract
Spine injury resulting from migration of previously implanted appendicular skeleton fixation hardware is rare. We present a 41-year-old man who had Steinmann fixation pins placed for a left clavicular fracture 2 years prior. He presented with a burning sensation over his biceps bilaterally and numbness over the left anterior chest and abdomen following a significant blunt traumatic injury. A CT scan revealed migration of a fractured Steinmann pin entering the left C8 neural foramen, traversing anterior to the spinal cord. The patient underwent a left C7 hemilaminectomy, foraminal decompression, and first rib resection to identify the extraforaminal portion of the pin and remove it under direct vision. He recovered uneventfully. We conclude that a principle of safe surgical removal includes adequate exposure to allow for direct visualization of the pin and neural structures. We review the evaluation and management strategies of this unusual condition.Entities:
Mesh:
Year: 2011 PMID: 22099073 DOI: 10.1016/j.jocn.2011.05.018
Source DB: PubMed Journal: J Clin Neurosci ISSN: 0967-5868 Impact factor: 1.961