Thiel-fixation preserves the non-linear load-deformation characteristic of spinal motion segments, but increases their flexibility.

Hans-Joachim Wilke1, Karin Werner, Kim Häussler, Michael Reinehr, Tobias M Böckers.   

Abstract

Human cadaveric specimens are recommended as the best option for in-vitro tests. However, fresh human spine specimens are often difficult to obtain. Further problems are the potential risk of infection and they can only be used over a limited test period. Therefore, the use of embalmed specimens is often discussed. The most common method is formalin fixation. However, this type of embalming can result in failure, because the biomechanical properties of the tissue is partially influenced. In recent years the development of the new method, the fixation according to Thiel, could provide an alternative to fresh or formalin-fixed specimens. The aim of the present study is to compare the biomechanical properties between fresh and Thiel-fixed spine specimens, and to compare the data to previous data of a test with formalin fixation. For the study, six L1-L2 spinal segments from 16-week-old calves were biomechanically tested. The parameters, range of motion and neutral zone, were determined in flexion/extension, right/left lateral bending and left/right axial rotation. The results showed that the specimens kept their non-linear load-deformation-characteristic after Thiel fixation. The range of motion of Thiel-fixed specimens increased relative to the unembalmed state by approximately 22% in flexion-extension, 23% in lateral bending (p<0.05) and 45% in axial rotation (p<0.05). In conclusion, the results still suggest a preference for fresh cadaveric spine specimens for quantitative biomechanical in-vitro testing, because they provide the best physiological conditions. However, for preliminary tests, which may only be used for orientation, embalmed specimens using the Thiel fixation method might serve as an alternative. Compared to formalin-fixated specimens which become approximately 5 times stiffer and completely lose their non-linear load-deformation-characteristic, as found in a previous study; the Thiel fixation maintains the non-linear load-deformation-characteristic but increases the range of motion.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22098913     DOI: 10.1016/j.jmbbm.2011.07.013

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  15 in total

Review 1.  The thoracolumbar fascia: anatomy, function and clinical considerations.

Authors:  F H Willard; A Vleeming; M D Schuenke; L Danneels; R Schleip
Journal:  J Anat       Date:  2012-05-27       Impact factor: 2.610

2.  Thiel-embalming technique: investigation of possible modification in embalming tissue as evaluation model for radiofrequency ablation.

Authors:  Pei-Yu Liao; Zhi-Gang Wang
Journal:  J Biomed Res       Date:  2019-04-08

Review 3.  Human body preservation - old and new techniques.

Authors:  Erich Brenner
Journal:  J Anat       Date:  2014-01-18       Impact factor: 2.610

4.  Mechanical characteristics of the maxillary sinus Schneiderian membrane ex vivo.

Authors:  Angel Insua; Florencio Monje-Gil; Lucía García-Caballero; Jordi Caballé-Serrano; Hom-Lay Wang; Alberto Monje
Journal:  Clin Oral Investig       Date:  2017-09-13       Impact factor: 3.573

5.  Knee kinematics are variously influenced by different correction angles in high tibial osteotomy (HTO).

Authors:  Baier Clemens; Keshmiri Armin; Greimel Felix; Krieg Bernd; Parik Lukas; Grifka Joachim; Maderbacher Guenther
Journal:  Int Orthop       Date:  2022-06-14       Impact factor: 3.479

6.  Intubation Biomechanics: Laryngoscope Force and Cervical Spine Motion during Intubation in Cadavers-Cadavers versus Patients, the Effect of Repeated Intubations, and the Effect of Type II Odontoid Fracture on C1-C2 Motion.

Authors:  Bradley J Hindman; Robert P From; Ricardo B Fontes; Vincent C Traynelis; Michael M Todd; M Bridget Zimmerman; Christian M Puttlitz; Brandon G Santoni
Journal:  Anesthesiology       Date:  2015-11       Impact factor: 7.892

7.  Characterization of trabecular bone density with ultra-short echo-time MRI at 1.5, 3.0 and 7.0 T--comparison with micro-computed tomography.

Authors:  Moritz C Wurnig; Maurizio Calcagni; David Kenkel; Magdalena Vich; Markus Weiger; Gustav Andreisek; Felix W Wehrli; Andreas Boss
Journal:  NMR Biomed       Date:  2014-08-04       Impact factor: 4.044

8.  Intubation biomechanics: laryngoscope force and cervical spine motion during intubation with Macintosh and Airtraq laryngoscopes.

Authors:  Bradley J Hindman; Brandon G Santoni; Christian M Puttlitz; Robert P From; Michael M Todd
Journal:  Anesthesiology       Date:  2014-08       Impact factor: 7.892

9.  From "silent teachers" to models.

Authors:  Roos Eisma; Tracey Wilkinson
Journal:  PLoS Biol       Date:  2014-10-21       Impact factor: 8.029

10.  Saturated salt solution method: a useful cadaver embalming for surgical skills training.

Authors:  Shogo Hayashi; Hiroshi Homma; Munekazu Naito; Jun Oda; Takahisa Nishiyama; Atsuo Kawamoto; Shinichi Kawata; Norio Sato; Tomomi Fukuhara; Hirokazu Taguchi; Kazuki Mashiko; Takeo Azuhata; Masayuki Ito; Kentaro Kawai; Tomoya Suzuki; Yuji Nishizawa; Jun Araki; Naoto Matsuno; Takayuki Shirai; Ning Qu; Naoyuki Hatayama; Shuichi Hirai; Hidekimi Fukui; Kiyoshige Ohseto; Tetsuo Yukioka; Masahiro Itoh
Journal:  Medicine (Baltimore)       Date:  2014-12       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.