Minimum analytical quality specifications of inter-laboratory comparisons: agreement among Spanish EQAP organizers.

Carmen Ricós1, Francisco Ramón, Angel Salas, Antonio Buño, Rafael Calafell, Jorge Morancho, Gabriella Gutiérrez-Bassini, Josep M Jou.   

Abstract

BACKGROUND: Four Spanish scientific societies organizing external quality assessment programs (EQAP) formed a working group to promote the use of common minimum quality specifications for clinical tests. Laboratories that do not meet the minimum specifications are encouraged to make immediate review of the analytical procedure affected and to implement corrective actions if necessary.
METHODS: The philosophy was to use the 95th percentile of results sent to EQAP (expressed in terms of percentage deviation from the target value) obtained for all results (except the outliers) during a cycle of 1 year. The target value for a number of analytes of the basic biochemistry program was established as the overall mean. However, because of the substantial discrepancies between routine methods for basic hematology, hormones, proteins, therapeutic drugs and tumor markers, the target in these cases was the peer group mean.
RESULTS: The resulting specifications were quite similar to those established in the US (CLIA), and Germany (Richtlinie).
CONCLUSIONS: The proposed specifications stand for the minimum level of quality to be attained for laboratories, to assure harmonized service performance. They have nothing to do with satisfying clinical requirements, which are the final level of quality to be reached, and that is strongly recommended in our organizations by means of documents, courses, symposiums and all types of educational activities.

Entities:  

Mesh:

Year:  2011        PMID: 22098436     DOI: 10.1515/CCLM.2011.787

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  5 in total

1.  Comparison of noninvasive and invasive point-of-care testing methods with reference method for hemoglobin measurement.

Authors:  Gamze Avcioglu; Cemil Nural; Fatma Meriç Yilmaz; Pervin Baran; Özcan Erel; Gülsen Yilmaz
Journal:  J Clin Lab Anal       Date:  2017-08-23       Impact factor: 2.352

2.  LEGO plot for simultaneous application of multiple quality requirements during trueness verification of quantitative laboratory tests.

Authors:  Hae-il Park; Hyojin Chae; Myungshin Kim; Jehoon Lee; Yonggoo Kim
Journal:  J Clin Lab Anal       Date:  2014-01-06       Impact factor: 2.352

3.  The importance of having a flexible scope ISO 15189 accreditation and quality specifications based on biological variation--the case of validation of the biochemistry analyzer Dimension Vista.

Authors:  Pilar Fernandez-Calle; Sandra Pelaz; Paloma Oliver; Maria Jose Alcaide; Ruben Gomez-Rioja; Antonio Buno; Jose Manuel Iturzaeta
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

4.  Effects of Cold Agglutinin on the Accuracy of Complete Blood Count Results and Optimal Sample Pretreatment Protocols for Eliminating Such Effects.

Authors:  John Hoon Rim; Myung Hee Chang; Joowon Oh; Heon Yung Gee; Jeong Ho Kim; Jongha Yoo
Journal:  Ann Lab Med       Date:  2018-07       Impact factor: 3.464

5.  Using Sigma metrics to establish analytical product performance requirements and optimize analytical performance of an in vitro diagnostic assay using a theoretical total PSA assay as an example.

Authors:  Victoria Petrides; Sharon Schneider
Journal:  Biochem Med (Zagreb)       Date:  2018-06-15       Impact factor: 2.313

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.