OBJECT: The cavernous sinus and surrounding regions-specifically the Meckel cave, posterior sector of the cavernous sinus itself, and the upper part of the petroclival region-are the location of a large variety of lesions that require individual consideration regarding treatment strategy. These regions may be reached for biopsy by a percutaneous needle inserted through the foramen ovale. The aim of this retrospective study was to evaluate the diagnostic accuracy of percutaneous biopsy in a consecutive series of 50 patients referred for surgery between 1991 and 2010. METHODS: Seven biopsies (14%) were unproductive and 43 (86%) were productive, among which 28 lesions subsequently underwent histopathological examination during a second (open) surgery. To evaluate the diagnostic accuracy of the procedure, results from surgery were compared with those from the biopsy. RESULTS: Sensitivity of the percutaneous biopsy was 0.83 (95% CI 0.52-0.98), specificity was 1 (95% CI 0.79-1), and κ coefficient was 0.81. CONCLUSIONS: Because of its valuable diagnostic accuracy, percutaneous biopsy of the cavernous sinus and surrounding regions should be performed in patients with parasellar masses when neuroimaging does not provide sufficient information of a histopathological nature. This procedure would enable patients to obtain the most appropriate therapy, such as resective surgery, corticosteroids, chemotherapy, radiotherapy, or radiosurgery.
OBJECT: The cavernous sinus and surrounding regions-specifically the Meckel cave, posterior sector of the cavernous sinus itself, and the upper part of the petroclival region-are the location of a large variety of lesions that require individual consideration regarding treatment strategy. These regions may be reached for biopsy by a percutaneous needle inserted through the foramen ovale. The aim of this retrospective study was to evaluate the diagnostic accuracy of percutaneous biopsy in a consecutive series of 50 patients referred for surgery between 1991 and 2010. METHODS: Seven biopsies (14%) were unproductive and 43 (86%) were productive, among which 28 lesions subsequently underwent histopathological examination during a second (open) surgery. To evaluate the diagnostic accuracy of the procedure, results from surgery were compared with those from the biopsy. RESULTS: Sensitivity of the percutaneous biopsy was 0.83 (95% CI 0.52-0.98), specificity was 1 (95% CI 0.79-1), and κ coefficient was 0.81. CONCLUSIONS: Because of its valuable diagnostic accuracy, percutaneous biopsy of the cavernous sinus and surrounding regions should be performed in patients with parasellar masses when neuroimaging does not provide sufficient information of a histopathological nature. This procedure would enable patients to obtain the most appropriate therapy, such as resective surgery, corticosteroids, chemotherapy, radiotherapy, or radiosurgery.
Authors: Barbara Casolla; Serena Candela; Antonio Ciacciarelli; Ludovico Ciolli; Andrea Romano; Michele Acqui; Maria Christina Cox; Giuliano Sette; Francesco Orzi Journal: J Neurol Surg B Skull Base Date: 2018-06-08
Authors: Matthew J Zdilla; Scott A Hatfield; Kennedy A McLean; Leah M Cyrus; Jillian M Laslo; H Wayne Lambert Journal: J Craniofac Surg Date: 2016-01 Impact factor: 1.046
Authors: Matthew J Zdilla; Scott A Hatfield; Kennedy A McLean; Jillian M Laslo; Leah M Cyrus; H Wayne Lambert Journal: J Craniofac Surg Date: 2016-01 Impact factor: 1.046
Authors: Martin Lorenzetti; Herculano Carvalho; Maria Cattoni; Antonio Gonçalves-Ferreira; José Pimentel; Joao Antuñes Journal: Surg Neurol Int Date: 2014-12-30
Authors: Marco V Corniola; Pierre-Hugues Roche; Michaël Bruneau; Luigi M Cavallo; Roy T Daniel; Mahmoud Messerer; Sebastien Froelich; Paul A Gardner; Fred Gentili; Takeshi Kawase; Dimitrios Paraskevopoulos; Jean Régis; Henry W S Schroeder; Theodore H Schwartz; Marc Sindou; Jan F Cornelius; Marcos Tatagiba; Torstein R Meling Journal: Brain Spine Date: 2022-01-21
Authors: E Suero Molina; J M Revuelta Barbero; C Ewelt; W Stummer; R L Carrau; D M Prevedello Journal: Neurosurg Rev Date: 2020-02-10 Impact factor: 3.042