Literature DB >> 2209752

Corneal autofluorescence in diabetic and penetrating keratoplasty patients as measured by fluorophotometry.

T R Stolwijk1, J A van Best, J P Boot, J A Oosterhuis.   

Abstract

At first it was verified that the major part of the fluorophotometer signal obtained when measuring corneal autofluorescence originated from fluorescence and not from scatter of excitation light at the corneal surface. The minimum percentage of the signal which can be attributed to fluorescence was determined using a fluorescence blocking filter placed in the excitation and fluorescence light path, respectively. The minimum percentages in two healthy controls, two diabetic patients and two patients after penetrating keratoplasty ranged from 75% to 93% (mean 84%). Then the corneal autofluorescence was determined in 22 healthy controls, 18 non-insulin-dependent diabetes mellitus (NIDDM). 23 insulin-dependent diabetes mellitus (IDDM) and 21 penetrating keratoplasty patients in order to detect a possible difference in autofluorescence as a result of diabetes or penetrating keratoplasty. The means of the corneal peak autofluorescence values in the NIDDM, IDDM and penetrating keratoplasty patient groups were significantly higher than that in the healthy control group (mean values in ng equivalent fluorescin ml-1: 18.0 +/- 4.2 S.D., 20.6 +/- 5.1 S.D., 17.9 +/- 5.5 S.D. and 13.7 +/- 3.7 S.D., respectively; P less than 0.01). The mean values in the NIDDM and IDDM patients did not differ significantly (P = 0.09). The autofluorescence values were independent of age in all four groups (linear correlation coefficient: r less than 0.47). The corneal peak autofluorescence was linearly correlated with the diabetes duration in the NIDDM and IDDM patients [r = 0.6, P = 0.02; increase: 0.36 ng equiv. fluorescein ml-1 yr diabetes-1]. Our results show that corneal autofluorescence is an easily obtained parameter which can be of assistance in evaluating corneal metabolism.

Entities:  

Mesh:

Year:  1990        PMID: 2209752     DOI: 10.1016/0014-4835(90)90152-k

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  7 in total

1.  Functional measurements on the enlarged endothelial cells of corneal transplants.

Authors:  W M Bourne
Journal:  Trans Am Ophthalmol Soc       Date:  1995

Review 2.  Optical quality of the diabetic eye: a review.

Authors:  A M Calvo-Maroto; R J Perez-Cambrodí; C Albarán-Diego; A Pons; A Cerviño
Journal:  Eye (Lond)       Date:  2014-08-15       Impact factor: 3.775

3.  Corneal autofluorescence in choroidal melanoma or in choroidal naevus.

Authors:  R P Müskens; J A Van Best; J C Bleeker; J E Keunen
Journal:  Br J Ophthalmol       Date:  2001-06       Impact factor: 4.638

4.  Topical timolol with and without benzalkonium chloride: epithelial permeability and autofluorescence of the cornea in glaucoma.

Authors:  C de Jong; T Stolwijk; E Kuppens; R de Keizer; J van Best
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-04       Impact factor: 3.117

5.  Topical timolol, corneal epithelial permeability and autofluorescence in glaucoma by fluorophotometry.

Authors:  E Kuppens; T Stolwijk; J van Best; R de Keizer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-04       Impact factor: 3.117

6.  Determination of basal tear turnover in insulin-dependent diabetes mellitus patients by fluorophotometry.

Authors:  T R Stolwijk; J A van Best; H H Lemkes; R J de Keizer; J A Oosterhuis
Journal:  Int Ophthalmol       Date:  1991-11       Impact factor: 2.031

7.  Effect of timolol with and without preservative on the basal tear turnover in glaucoma.

Authors:  E V Kuppens; C A de Jong; T R Stolwijk; R J de Keizer; J A van Best
Journal:  Br J Ophthalmol       Date:  1995-04       Impact factor: 4.638

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.