Literature DB >> 22097082

Systematic evaluation of biofilm models for engineering practice: components and critical assumptions.

J P Boltz1, E Morgenroth, D Brockmann, C Bott, W J Gellner, P A Vanrolleghem.   

Abstract

Biofilm models are valuable tools for the design and evaluation of biofilm-based processes despite several uncertainties including the dynamics and rate of biofilm detachment, concentration gradients external to the biofilm surface, and undefined biofilm reactor model calibration protocol. The present investigation serves to (1) systematically evaluate critical biofilm model assumptions and components and (2) conduct a sensitivity analysis with the aim of identifying parameter subsets for biofilm reactor model calibration. AQUASIM was used to describe submerged-completely mixed combined carbon oxidation and nitrification IFAS and MBBR systems, and tertiary nitrification and denitrification MBBRs. The influence of uncertainties in model parameters on relevant model outputs was determined for simulated scenarios by means of a local sensitivity analysis. To obtain reasonable simulation results for partially penetrated biofilms that accumulated a substantial thickness in the modelled biofilm reactor (e.g. 1,000 microm), an appropriate biofilm discretization was applied to properly model soluble substrate concentration gradients and, consistent with the assumed mechanism for describing biofilm biomass distribution, biofilm biomass spatial variability. The MTBL thickness had a significant impact on model results for each of the modelled reactor configurations. Further research is needed to develop a mathematical description (empirical or otherwise) of the MTBL thickness that is relevant to modern biofilm reactors. No simple recommendations for a generally applicable calibration protocol are provided, but sensitivity analysis has been proven to be a powerful tool for the identification of highly sensitive parameter subsets for biofilm (reactor) model calibration.

Entities:  

Mesh:

Year:  2011        PMID: 22097082     DOI: 10.2166/wst.2011.709

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  3 in total

1.  DIFFUSION IN BIOFILMS RESPIRING ON ELECTRODES.

Authors:  Rs Renslow; Jt Babauta; Pd Majors; H Beyenal
Journal:  Energy Environ Sci       Date:  2012-11-15       Impact factor: 38.532

2.  How to measure diffusion coefficients in biofilms: A critical analysis.

Authors:  Lenno van den Berg; Mark C M van Loosdrecht; Merle K de Kreuk
Journal:  Biotechnol Bioeng       Date:  2020-12-25       Impact factor: 4.530

3.  Heterogeneous diffusion in aerobic granular sludge.

Authors:  Lenno van den Berg; Catherine M Kirkland; Joseph D Seymour; Sarah L Codd; Mark C M van Loosdrecht; Merle K de Kreuk
Journal:  Biotechnol Bioeng       Date:  2020-08-06       Impact factor: 4.395

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.