Literature DB >> 22096111

Beneficial effect of real-time continuous glucose monitoring system on glycemic control in type 1 diabetic patients: systematic review and meta-analysis of randomized trials.

A Szypowska1, A Ramotowska, K Dzygalo, D Golicki.   

Abstract

OBJECTIVE: Real-time continuous glucose monitoring (RT-CGM) provides detailed information on glucose patterns and trends, thus allowing the patients to manage their diabetes more effectively.
DESIGN: The aim of this study was to explore the potential beneficial effects of the use of RT-CGM on diabetes management compared with self blood glucose measurement (SBGM) in patients with type 1 diabetes mellitus (T1DM), by means of a systematic review and meta-analysis of randomized controlled trials (RCTs).
METHODS: MEDLINE, EMBASE, and the Cochrane Library were searched through by two independent investigators for RCTs concerning the use of RT-CGM in patients with T1DM. Only studies with a similar insulin regimen in the experimental and control groups were included in the analysis.
RESULTS: Seven RCTs (n=948) met the inclusion criteria. Combined data from all studies showed better HbA1c reduction in subjects using RT-CGM compared with those using SBGM (mean difference (MD) -0.25; 95% confidence interval (95% CI): from -0.34 to -0.17; P<0.001). Patients treated with insulin pump and RT-CGM had a lower HbA1c level compared with subjects managed with insulin pump and SBGM (four RCTs, n=497; MD -0.26; 95% CI: from -0.43 to -0.10; P=0.002). The benefits of applying RT-CGM were not associated with an increasing rate of major hypoglycemic episodes. The use of RT-CGM for over 60-70% of time was associated with a significant lowering of HbA1c.
CONCLUSIONS: RT-CGM is more beneficial than SBGM in reducing HbA1c in patients with type 1 diabetes. Further studies are needed to evaluate the efficacy of this system in the pediatric population, especially in very young children.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22096111     DOI: 10.1530/EJE-11-0642

Source DB:  PubMed          Journal:  Eur J Endocrinol        ISSN: 0804-4643            Impact factor:   6.664


  21 in total

1.  Are Systematic Reviews and Meta-Analyses Appropriate Tools for Assessing Evolving Medical Device Technologies?

Authors:  David Price; Claudia Graham; Christopher G Parkin; Thomas A Peyser
Journal:  J Diabetes Sci Technol       Date:  2015-09-29

2.  Clinical Use of Continuous Glucose Monitoring in Pediatrics.

Authors:  Rayhan A Lal; David M Maahs
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

Review 3.  Role of continuous glucose monitoring in the management of diabetic pregnancy.

Authors:  Niranjala M Hewapathirana; Esther O'Sullivan; Helen R Murphy
Journal:  Curr Diab Rep       Date:  2013-02       Impact factor: 4.810

Review 4.  Evidence-informed clinical practice recommendations for treatment of type 1 diabetes complicated by problematic hypoglycemia.

Authors:  Pratik Choudhary; Michael R Rickels; Peter A Senior; Marie-Christine Vantyghem; Paola Maffi; Thomas W Kay; Bart Keymeulen; Nobuya Inagaki; Frantisek Saudek; Roger Lehmann; Bernhard J Hering
Journal:  Diabetes Care       Date:  2015-06       Impact factor: 19.112

Review 5.  Management of type 1 diabetes in children and adolescents.

Authors:  Vandana Jain
Journal:  Indian J Pediatr       Date:  2013-10-11       Impact factor: 1.967

Review 6.  The evidence base for diabetes technology: appropriate and inappropriate meta-analysis.

Authors:  John C Pickup
Journal:  J Diabetes Sci Technol       Date:  2013-11-01

7.  Preclinical Evaluation of Poly(HEMA-co-acrylamide) Hydrogels Encapsulating Glucose Oxidase and Palladium Benzoporphyrin as Fully Implantable Glucose Sensors.

Authors:  Rachel M Unruh; Jason R Roberts; Scott P Nichols; Soya Gamsey; Natalie A Wisniewski; Michael J McShane
Journal:  J Diabetes Sci Technol       Date:  2015-06-17

8.  Lessons learned from a pilot RCT of simultaneous versus delayed initiation of continuous glucose monitoring in children and adolescents with type 1 diabetes starting insulin pump therapy.

Authors:  Patricia Olivier; Margaret L Lawson; Celine Huot; Christine Richardson; Meranda Nakhla; Judette Romain
Journal:  J Diabetes Sci Technol       Date:  2014-02-27

9.  Use of Personal Continuous Glucose Monitoring Device Is Associated With Reduced Risk of Hypoglycemia in a 16-Week Clinical Trial of People With Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion.

Authors:  Morten Hasselstrøm Jensen; Peter Vestergaard; Irl B Hirsch; Ole Hejlesen
Journal:  J Diabetes Sci Technol       Date:  2020-09-18

10.  Technological Ecological Momentary Assessment Tools to Study Type 1 Diabetes in Youth: Viewpoint of Methodologies.

Authors:  Mary Katherine Ray; Alana McMichael; Maria Rivera-Santana; Jacob Noel; Tamara Hershey
Journal:  JMIR Diabetes       Date:  2021-06-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.