Literature DB >> 22095751

An experimental glenoid rim strain analysis for an improved reverse anatomy shoulder implant fixation.

Simon C Mordecai1, Simon M Lambert, Jay M Meswania, Gordon W Blunn, Ian L Bayley, Stephen J G Taylor.   

Abstract

Loosening of glenoid components in TSA is a main cause of failure. In reverse anatomy TSA designs used for unstable joints, fixation is particularly demanding. Strains developed around the glenoid rim of biomechanical sawbone scapulae implanted with (a) the original fixed-fulcrum Bayley-Walker glenoid prosthesis in current clinical use, and (b) a revised version with conical cross-section, were compared. The conical shape of the revised design was hypothesized to produce greater strains in the glenoid rim than the original tapered screw design. The 2D strain field at three accessible locations around the rim of each scapula was measured with three-element rosette strain gauges for two types of simulated cancellous bone fill under applied physiologically relevant loads. The average strain energy densities around the rim for the conical design were greater than for the original design by a factor of 1.55-2.25 for all loading conditions. Results indicate that a significantly greater proportion of load was directed toward cortical bone in the conical design, thus promoting cortical bone loading.
Copyright © 2011 Orthopaedic Research Society.

Entities:  

Mesh:

Year:  2011        PMID: 22095751     DOI: 10.1002/jor.22015

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  4 in total

1.  Constrained fixed-fulcrum reverse shoulder arthroplasty improves functional outcome in epileptic patients with recurrent shoulder instability.

Authors:  Tanujan Thangarajah; Deborah Higgs; J I L Bayley; Simon M Lambert
Journal:  World J Orthop       Date:  2016-07-18

2.  Effects of Increased Retroversion Angle on Glenoid Baseplate Fixation in Reverse Total Shoulder Arthroplasty: A Finite Element Analysis.

Authors:  Richard J Friedman; Shuchun Sun; Xin She; Jordan Esposito; Josef Eichinger; Hai Yao
Journal:  Semin Arthroplasty       Date:  2021-01-02

Review 3.  A Critical Review on Prosthetic Features Available for Reversed Total Shoulder Arthroplasty.

Authors:  Bart Middernacht; Alexander Van Tongel; Lieven De Wilde
Journal:  Biomed Res Int       Date:  2016-12-25       Impact factor: 3.411

4.  Influence of Glenosphere and baseplate parameters on Glenoid bone strains in reverse shoulder Arthroplasty.

Authors:  Leo Pauzenberger; Cory Dwyer; Elifho Obopilwe; Michael D Nowak; Mark Cote; Anthony A Romeo; Augustus D Mazzocca; Felix Dyrna
Journal:  BMC Musculoskelet Disord       Date:  2019-12-05       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.