Literature DB >> 22094451

Impact of pulmonary vein anatomy assessed by cardiac magnetic resonance imaging on endoscopic pulmonary vein isolation in consecutive patients.

Andreas Metzner1, Dietmar Kivelitz, Boris Schmidt, Alexander Fuernkranz, Erik Wissner, Roland R Tilz, Melanie Konstantinidou, Andreas Rillig, Yazuhiro Yoshiga, Shibu Mathew, Feifan Ouyang, Karl-Heinz Kuck.   

Abstract

AIMS: Recently, the novel endoscopic ablation system (EAS) was introduced and proved its potential for successful pulmonary vein isolation (PVI) in patients suffering from paroxysmal atrial fibrillation (PAF). The current study will investigate the impact of pulmonary vein (PV) anatomy assessed by pre-interventional cardiac magnetic resonance imaging (CMRI) on endoscopic PVI. METHODS AND
RESULTS: Fifty-one patients (23 females, age 57 ± 9 years) with a long history (5 ± 5 years) of drug-refractory PAF were included into our analysis. Cardiac magnetic resonance imaging was performed in all patients before ablation. Each CMRI was evaluated for the number of PVs, for separate or common insertion of ipsilateral PVs, for the PV diameter and PV shape (round vs. oval), for the level of first PV branching, and for the level of insertion of the right inferior PV (RIPV) into the left atrium (LA), respectively. Pulmonary vein isolation was performed using exclusively the novel EAS. The CMRI findings were correlated with the ablation results. A total of 195 PVs were identified and targeted. In 192 of 195 (98%) PVs successful isolation was achieved using the novel EAS irrespective of the PV diameter, the PV shape, the level of PV branching, or the type of insertion of the PV into the LA. There was no statistical significance when correlating the CMRI findings with acute isolation success of the respective PVs or the number of laser applications needed until PVI (P> 0.05). A low level of insertion of the RIPV into the LA was not associated with PVI failure or a higher number of laser applications (P> 0.05).
CONCLUSIONS: The majority of PVs could have been targeted and successfully isolated using exclusively the novel EAS irrespective of their anatomy assessed by pre-interventional CMRI. Considering the economical impact of CMRI and its minor influence on ablation strategy, success, and safety it is not an essential pre-requisite for subsequent successful EAS-based PVI.

Entities:  

Mesh:

Year:  2011        PMID: 22094451     DOI: 10.1093/europace/eur356

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  5 in total

1.  Anatomical predictors for successful pulmonary vein isolation using balloon-based technologies in atrial fibrillation.

Authors:  Alexey Tsyganov; Jan Petru; Jan Skoda; Lucie Sediva; Pavel Hala; Jiri Weichet; Marek Janotka; Milan Chovanec; Petr Neuzil; Vivek Y Reddy
Journal:  J Interv Card Electrophysiol       Date:  2015-10-16       Impact factor: 1.900

2.  Effect of left atrial volume and pulmonary vein anatomy on outcome of nMARQ™ catheter ablation of paroxysmal atrial fibrillation.

Authors:  Giuseppe Stabile; Matteo Anselmino; Ezio Soldati; Ermengildo De Ruvo; Francesco Solimene; Assunta Iuliano; Luigi Sciarra; Maria Grazia Bongiorni; Leonardo Calò; Fiorenzo Gaita
Journal:  J Interv Card Electrophysiol       Date:  2016-10-06       Impact factor: 1.900

Review 3.  Role of cardiac computed tomography and cardiovascular magnetic resonance imaging in guiding management and treatment of patients with atrial fibrillation: state of the art review.

Authors:  Wael A Aljaroudi; Walid S Saliba; Oussama M Wazni; Wael A Jaber
Journal:  J Nucl Cardiol       Date:  2013-02-12       Impact factor: 5.952

4.  Pulmonary vein anatomy assessed by cardiac magnetic resonance imaging in patients undergoing initial atrial fibrillation ablation: implications for novel ablation technologies.

Authors:  Faisal M Merchant; Mathew R Levy; Shahriar Iravanian; Edward C Clermont; Heval M Kelli; Robert L Eisner; Mikhael F El-Chami; Angel R Leon; David B Delurgio
Journal:  J Interv Card Electrophysiol       Date:  2016-01-26       Impact factor: 1.900

5.  Evaluation of different ablation strategies verifying the optimal overlap ratio in point-by-point laser balloon ablation for patients with atrial fibrillation.

Authors:  Takahiko Nagase; Ruiko Seki; So Asano; Hiroshi Fukunaga; Kazuhiro Terashima; Kei Mabuchi; Kanki Inoue; Kohei Tanizaki; Nobuo Iguchi; Junichi Nitta; Mitsuaki Isobe
Journal:  Heart Rhythm O2       Date:  2021-07-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.