The objectives of this study are to evaluate the effect of couch attenuation on quality assurance (QA) results and to present a couch top model for Monte Carlo (MC) dose calculation for RapidArc treatments. The IGRT couch top is modelled in Eclipse as a thin skin of higher density material with a homogeneous fill of foam of lower density and attenuation. The IGRT couch structure consists of two longitudinal sections referred to as thick and thin. The Hounsfield Unit (HU) characterization of the couch structure was determined using a cylindrical phantom by comparing ion chamber measurements with the dose predicted by the treatment planning system (TPS). The optimal set of HU for the inside of the couch and the surface shell was found to be respectively -960 and -700 HU in agreement with Vanetti et al (2009 Phys. Med. Biol. 54 N157-66). For each plan, the final dose calculation was performed with the thin, thick and without the couch top. Dose differences up to 2.6% were observed with TPS calculated doses not including the couch and up to 3.4% with MC not including the couch and were found to be treatment specific. A MC couch top model was created based on the TPS geometrical model. The carbon fibre couch top skin was modelled using carbon graphite; the density was adjusted until good agreement with experimental data was observed, while the density of the foam inside was kept constant. The accuracy of the couch top model was evaluated by comparison with ion chamber measurements and TPS calculated dose combined with a 3D gamma analysis. Similar to the TPS case, a single graphite density can be used for both the thin and thick MC couch top models. Results showed good agreement with ion chamber measurements (within 1.2%) and with TPS (within 1%). For each plan, over 95% of the points passed the 3D gamma test.

Entities:  

Mesh:

Year:  2011        PMID: 22094392     DOI: 10.1088/0031-9155/56/24/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Three-dimensional conformal intensity-modulated radiation therapy of left femur foci does not damage the sciatic nerve.

Authors:  Wanlong Xu; Xibin Zhao; Qing Wang; Jungang Sun; Jiangbo Xu; Wenzheng Zhou; Hao Wang; Shigui Yan; Hong Yuan
Journal:  Neural Regen Res       Date:  2014-10-15       Impact factor: 5.135

2.  Quantification and comparison the dosimetric impact of two treatment couch model in VMAT.

Authors:  Ruohui Zhang; Yulan Gao; Wenwen Bai
Journal:  J Appl Clin Med Phys       Date:  2017-11-02       Impact factor: 2.102

3.  Dosimetric effects of immobilization devices on SABR for lung cancer using VMAT technique.

Authors:  Jong In Park; Sung-Joon Ye; Hak Jae Kim; Jong Min Park
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

4.  Dose Calculation Comparisons between Three Modern Treatment Planning Systems.

Authors:  Courtney Bosse; Ganesh Narayanasamy; Daniel Saenz; Pamela Myers; Neil Kirby; Karl Rasmussen; Panayiotis Mavroidis; Niko Papanikolaou; Sotirios Stathakis
Journal:  J Med Phys       Date:  2020-10-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.