Literature DB >> 22093504

Implantable cardioverter-defibrillator patients who are upgraded and respond to cardiac resynchronization therapy have less ventricular arrhythmias compared with nonresponders.

Joep Thijssen1, C Jan Willem Borleffs, Victoria Delgado, Johannes B van Rees, Eline A Q Mooyaart, Rutger J van Bommel, Lieselot van Erven, Eric Boersma, Jeroen J Bax, Martin J Schalij.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate the impact of upgrading implantable cardioverter-defibrillator (ICD) therapy to cardiac resynchronization therapy (CRT) combined with defibrillator (CRT-D) on the occurrence of ventricular arrhythmia (VA) and appropriate ICD therapies.
BACKGROUND: CRT has been shown to improve left ventricular (LV) systolic function and induce reverse LV remodeling. In addition, it has been hypothesized that CRT may reduce the incidence of VA.
METHODS: Heart failure patients receiving an upgrade from ICD to CRT-D were evaluated. Patients were considered responders to CRT if LV end-systolic volume reduced ≥15% at 6 months of follow-up. Episodes of VA, triggering device therapy (anti-tachycardia pacing and shocks) were recorded before and after upgrade for the overall population. In addition, these outcomes were compared between CRT responders and nonresponders during the follow-up period after CRT response was assessed.
RESULTS: One hundred fifteen patients (93 males [81%], age 65 ± 12 years) were evaluated during a mean follow-up of 54 ± 34 months before CRT-D upgrade and 37 ± 27 months after upgrade. In CRT responders (n = 70), the frequency of VA requiring appropriate device therapy demonstrated a trend toward a decrease from 0.51 ± 0.79 to 0.30 ± 0.59 per patient per year after CRT-D upgrade (p = 0.052). In CRT nonresponders (n = 45), the frequency of VA requiring appropriate device therapy significantly increased from 0.40 ± 0.69 to 1.21 ± 2.53 per patient per year after CRT-D upgrade (p = 0.014).
CONCLUSIONS: After upgrade from ICD to CRT-D, nonresponders to CRT showed a significant increase in VA burden requiring appropriate device therapy.
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22093504     DOI: 10.1016/j.jacc.2011.08.038

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  6 in total

1.  Impact of myocardial viability assessed by myocardial perfusion imaging on ventricular tachyarrhythmias in cardiac resynchronization therapy.

Authors:  David Žižek; Marta Cvijić; Luka Ležaić; Barbara Gužič Salobir; Igor Zupan
Journal:  J Nucl Cardiol       Date:  2013-10-18       Impact factor: 5.952

2.  Biventricular / left ventricular pacing in hypertrophic obstructive cardiomyopathy: an overview.

Authors:  Radu Vatasescu; Reinder Evertz; Lluis Mont; Marta Sitges; Josep Brugada; Antonio Berruezo
Journal:  Indian Pacing Electrophysiol J       Date:  2012-05-20

3.  Upgrade from ICD to CRT-D: clinical and haemodynamic impact of biventricular pacing in a patient with acquired long QT syndrome.

Authors:  Damian Kawecki; Janusz Dola; Wojciech Jacheć; Celina Wojciechowska; Stanisław Morawski; Andrzej Tomasik; Ewa Nowalany-Kozielska
Journal:  Open Med (Wars)       Date:  2015-01-15

4.  Synchronization of repolarization after cardiac resynchronization therapy: A combined clinical and modeling study.

Authors:  Nienke J Verzaal; Caroline J M van Deursen; Simone Pezzuto; Liliane Wecke; Wouter M van Everdingen; Kevin Vernooy; Tammo Delhaas; Angelo Auricchio; Frits W Prinzen
Journal:  J Cardiovasc Electrophysiol       Date:  2022-06-11       Impact factor: 2.942

Review 5.  Importance of Implantable Cardioverter-Defibrillator Back-Up in Cardiac Resynchronization Therapy Recipients: A Systematic Review and Meta-Analysis.

Authors:  Sérgio Barra; Rui Providência; Anthony Tang; Patrick Heck; Munmohan Virdee; Sharad Agarwal
Journal:  J Am Heart Assoc       Date:  2015-11-06       Impact factor: 5.501

6.  Association left ventricular lead and ventricular arrhythmias after upgrade to cardiac resynchronization therapy in patients with implantable cardioverter defibrillators.

Authors:  Mitsuharu Kawamura; Shuhei Arai; Kosuke Yoshikawa; Toshihiko Gokan; Ko Ogawa; Akinori Ochi; Yoshimi Onishi; Yumi Munetsugu; Hiroyuki Ito; Tatsuya Onuki; Youichi Kobayashi; Toshiro Shinke
Journal:  Clin Cardiol       Date:  2019-05-13       Impact factor: 2.882

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.