Applicability of multisyringe chromatography coupled to cold-vapor atomic fluorescence spectrometry for mercury speciation analysis.

J L Guzmán-Mar1, L Hinojosa-Reyes, A M Serra, A Hernández-Ramírez, V Cerdà.   

Abstract

In this paper, a novel automatic approach for the speciation of inorganic mercury (Hg(2+)), methylmercury (MeHg(+)) and ethylmercury (EtHg(+)) using multisyringe chromatography (MSC) coupled to cold-vapor atomic fluorescence spectrometry (CV/AFS) was developed. For the first time, the separation of mercury species was accomplished on a RP C18 monolithic column using a multi-isocratic elution program. The elution protocol involved the use of 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)-acetonitrile (99:1, v/v), followed by 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)-acetonitrile (90:10, v/v). The eluted mercury species were then oxidized under post-column UV radiation and reduced using tin(II) chloride in an acidic medium. Subsequently, the generated mercury metal were separated from the reaction mixture and further atomized in the flame atomizer and detected by AFS. Under the optimized experimental conditions, the limits of detection (3σ) were found to be 0.03, 0.11 and 0.09 μg L(-1) for MeHg(+), Hg(2+) and EtHg(+), respectively. The relative standard deviation (RSD, n=6) of the peak height for 3, 6 and 3 μg L(-1) of MeHg(+), Hg(2+) and EtHg(+) (as Hg) ranged from 2.4 to 4.0%. Compared with the conventional HPLC-CV/AFS hyphenated systems, the proposed MSC-CV/AFS system permitted a higher sampling frequency and low instrumental and operational costs. The developed method was validated by the determination of a certified reference material DORM-2 (dogfish muscle), and was further applied for the determination of mercury species environmental and biological samples.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Year:  2011        PMID: 22093339     DOI: 10.1016/j.aca.2011.09.037

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Preconcentration of Pb(II) by using Mg(II)-doped NiFe2O4 nanoparticles as a magnetic solid phase extraction agent.

Authors:  Hossein Abdolmohammad-Zadeh; Arezu Salimi
Journal:  Mikrochim Acta       Date:  2018-06-28       Impact factor: 5.833

2.  Determination of Cd2+ and Pb2+ Based on Mesoporous Carbon Nitride/Self-Doped Polyaniline Nanofibers and Square Wave Anodic Stripping Voltammetry.

Authors:  Chang Zhang; Yaoyu Zhou; Lin Tang; Guangming Zeng; Jiachao Zhang; Bo Peng; Xia Xie; Cui Lai; Beiqing Long; Jingjing Zhu
Journal:  Nanomaterials (Basel)       Date:  2016-01-04       Impact factor: 5.076

3.  Nanostructured carbon black for simultaneous electrochemical determination of trace lead and cadmium by differential pulse stripping voltammetry.

Authors:  Ruigang Xie; Lingli Zhou; Cuiling Lan; Fangfang Fan; Ruifeng Xie; Hongyu Tan; Tiansheng Xie; Lingmin Zhao
Journal:  R Soc Open Sci       Date:  2018-07-25       Impact factor: 2.963

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.