Literature DB >> 22093039

Evaluation of the safety and efficiency of novel metallic ultrasonic scaler tip on titanium surfaces.

Seung-Ho Baek1, Won-Jun Shon, Kwang-Shik Bae, Kee-Yeon Kum, Woo-Cheol Lee, Young-Seok Park.   

Abstract

AIM: To evaluate the safety and efficiency of novel ultrasonic scaler tips, conventional stainless-steel tips, and plastic tips on titanium surfaces.
MATERIAL AND METHODS: Mechanical instrumentation was carried out using conventional ultrasonic scalers (EMS, Nyon, Switzerland) with novel metallic implant tip (BS), a plastic-headed tip (ES), a plastic tip (PS) and a conventional stainless-steel tip (CS) on 10 polished commercially pure titanium disks (Grade II) per group. Arithmetic mean roughness (R(a) ) and maximum height roughness (R(y) ) of titanium samples were measured and dissipated power of the scaler tip in the tip-surface junction was estimated to investigate the scaling efficiency. The instrumented surface morphology of samples was viewed with a scanning electron microscope (SEM) and surface profile of the each sample was investigated using contact mode with a commercial atomic force microscope (AFM).
RESULTS: There were no significant differences in surface roughness (R(a) and R(y) ) among BS, ES, and PS group. However, CS group showed significant higher surface roughness (R(a) and R(y) ). The efficiency of CS tip is twice as much higher than that of BS tip, the efficiency of BS tip is 20 times higher than that of PS tip, and the efficiency of BS tip is 90 times higher than that of ES tip.
CONCLUSION: Novel metallic copper alloy ultrasonic scaler tips may minimally influence the titanium surface, similar to plastic tip. Therefore, they can be a suitable instrument for implant maintenance therapy.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22093039     DOI: 10.1111/j.1600-0501.2011.02302.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

1.  Evaluation of the safety and efficiency of novel metallic implant scaler tips manufactured by the powder injection molding technique.

Authors:  Kyung A Chun; Kee-Yeon Kum; Woo-Cheol Lee; Seung-Ho Baek; Hae-Won Choi; Won-Jun Shon
Journal:  BMC Oral Health       Date:  2017-07-11       Impact factor: 2.757

2.  Mechanical Properties and Wear Resistance of Commercial Stainless Steel Used in Dental Instruments.

Authors:  Hye-Bin Go; Jae-Yun Bang; Kyoung-Nam Kim; Kwang-Mahn Kim; Jae-Sung Kwon
Journal:  Materials (Basel)       Date:  2021-02-09       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.