Literature DB >> 22092887

Are marginal bone levels and implant stability/mobility affected by single-stage platform switched dental implants? A comparative clinical study.

Erhan Dursun1, Ibrahim Tulunoglu, Pınar Canpınar, Serdar Uysal, Ferda Alev Akalın, Tolga F Tözüm.   

Abstract

OBJECTIVES: The aim of this study was to evaluate short-term bone level and stability/mobility measurement alterations at platform switched (PS) and standard platform (SP) implants placed in mandibular premolar/molar regions using a single-stage protocol.
MATERIALS AND METHODS: Sixteen PS and 16 SP implants restorated with fixed prosthesis were included. Standard implant dimensions were used for both implant systems. After 3 months of osseointegration, implants were connected to abutments and final restorations were performed. Marginal bone loss was measured by standardized periapical radiographs. Implant stability/mobility was determined by resonance frequency analysis (RFA) and mobility measuring (MM) device values. Peri-implant parameters were evaluated with clinical periodontal indices and all parameters were assessed at baseline, 1, 3, and 6 months after the surgery.
RESULTS: After 6 months, all implants showed uneventful healing. Radiographic evaluation showed a mean bone loss of 0.72 mm for PS and 0.56 mm for SP implants, and there were no significant differences between implant types. At 6 months, mean implant stability quotient (ISQ) values were 73.38 and 77 for PS and SP implants, respectively. Mean MM values were -4.75 for PS and -6.38 for SP implants. Mean MM values were lower for SP implants compared to PS implants at all time points. No significant differences were detected between implant types according to clinical peri-implant parameters.
CONCLUSIONS: The micro-gap at crestal level which immediately exposed to the oral cavity in non-submerged two part implants seems to have adverse influence on the marginal bone level.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22092887     DOI: 10.1111/j.1600-0501.2011.02277.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

1.  Radiographic evaluation of conical tapered platform-switched implants in the posterior mandible: 1-year results of a two-center prospective study.

Authors:  Maximilian Moergel; Salomão Rocha; Ana Messias; Pedro Nicolau; Fernando Guerra; Wilfried Wagner
Journal:  Clin Oral Implants Res       Date:  2015-06-21       Impact factor: 5.977

2.  Repeatability of the resonance frequency analysis values in implants with a new technology.

Authors:  M-C Díaz-Castro; A Falcao; P López-Jarana; C Falcao; J-V Ríos-Santos; A Fernández-Palacín; M Herrero-Climent
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01

Review 3.  Impact of platform switching on marginal peri-implant bone-level changes. A systematic review and meta-analysis.

Authors:  Frank Peter Strietzel; Konrad Neumann; Moritz Hertel
Journal:  Clin Oral Implants Res       Date:  2014-01-20       Impact factor: 5.977

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.