Literature DB >> 22092589

Clinical and radiographic evaluation of NobelActive(TM) dental implants.

Danny S W Ho1, Stephen C H Yeung, Kwan Yat Zee, Bradley Curtis, Peter Hell, Vijay Tumuluri.   

Abstract

OBJECTIVES: To conduct a randomised controlled trial to evaluate the short-term clinical and radiographic efficacy of the NobelActive™ system and to evaluate the relative importance of achieving primary stability at placement.
MATERIALS AND METHODS: A total of 32 subjects were recruited and, using a split-mouth design, the NobelActive(TM) implant was compared with a contralaterally matched Brånemark implant. Both implants were placed in a single surgical procedure into healed sites using a one-stage protocol and reviewed at monthly intervals. NobelActive(TM) implants were functionally loaded with provisional restorations at 1 month and all implants were restored with final crowns 3 months post-implant placement. The implant was assessed using peak insertion torque values, resonance frequency analysis (RFA), clinical parameters, digital subtraction radiography, and cone beam computed tomography.
RESULTS: The insertion torque was significantly greater for the NobelActive(TM) implant group (P = 0.02), although no observable difference in RFA values were found. Preliminary results of 6 months follow-up suggest comparable clinical and radiographic healing responses between the test and control implants. Within the limits of the sample population, the survival rates were lower with the test implants, although this difference was not statistically significant.
CONCLUSIONS: The NobelActive(TM) implant system requires higher insertion torques and can also achieve greater primary stability compared with a control implant system. Short-term survival and marginal bone levels of NobelActive(TM) and control implants are comparable, although the NobelActive(TM) implant system appeared to be more technique-sensitive.
© 2011 John Wiley & Sons A/S.

Mesh:

Substances:

Year:  2011        PMID: 22092589     DOI: 10.1111/j.1600-0501.2011.02313.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  7 in total

Review 1.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

2.  Relevant Design Aspects to Improve the Stability of Titanium Dental Implants.

Authors:  M Herrero-Climent; P López-Jarana; B F Lemos; F J Gil; C Falcão; J V Ríos-Santos; B Ríos-Carrasco
Journal:  Materials (Basel)       Date:  2020-04-18       Impact factor: 3.623

3.  Clinicoradiographic Evaluation of Long-term Efficacy and Risk Factors Associated with Dental Implants used for Full Mouth Rehabilitation.

Authors:  Gaurav Chahal; Bipin Kumar Yadav; Rajesh Kumar Thakur; Roseka Saini; Mukesh Kumar; Kumar Saurabh
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

4.  A Retrospective Observational Study Assessing the Clinical Outcomes of a Novel Implant System with Low-Speed Site Preparation Protocol and Tri-Oval Implant Geometry.

Authors:  Giacomo Fabbri; Tristan Staas; Istvan Urban
Journal:  J Clin Med       Date:  2022-08-18       Impact factor: 4.964

5.  The effect of implant placement torque on crestal bone remodeling after 1 year of loading.

Authors:  Salwa Aldahlawi; Angela Demeter; Tassos Irinakis
Journal:  Clin Cosmet Investig Dent       Date:  2018-10-09

6.  Retrospective cohort study of 4,591 dental implants: Analysis of risk indicators for bone loss and prevalence of peri-implant mucositis and peri-implantitis.

Authors:  David French; H Michelle Grandin; Ronen Ofec
Journal:  J Periodontol       Date:  2019-02-06       Impact factor: 6.993

7.  Long-Term Efficacy of Variable-Thread Tapered Implants-A Retrospective, Clinical and Radiological Evaluation.

Authors:  Oliver Blume; Eva Maria Schnödt; Michael Back; Jan Ir Wildenhof; Florian A Probst; Sven Otto
Journal:  Medicina (Kaunas)       Date:  2020-10-27       Impact factor: 2.430