AIM: The aim of the study was to investigate the influence of cortical bone and increasing implant fixture length on primary stability. Further investigation considered the correlation between the presence of cortical bone at the marginal bone and implant stability measured by insertion torque (IT) and resonance frequency analysis (RFA), as well as implant length, were determined.
MATERIALS AND METHODS: Two different types of polyurethane bone models were compared. (Group 1: with cortical and cancellous bone; Group 2: with cancellous bone only). A total of 60 external type implants (∅ 4.1, OSSTEM(®), US II(®)) with different lengths (7, 10, and 13 mm) were used. IT was recorded automatically by a computer which was connected to the Implant fixture installation device during the placement. RFA was conducted to quantify the primary implant stability quotient (ISQ). All two measurements were repeated 10 times for each group.
RESULTS: All these differences were statistically significant between the two groups (P < 0.001) and intragroups (P < 0.001). Upon comparing the IT, cortical bone appears to have a greater influence on implant stability than implant lengths, whereas the RFA value strongly affects implant length rather than the presence of the crestal cortical bone.
CONCLUSIONS: The quantitative biomechanical evaluations clearly demonstrated that primary implant stability seems to be influenced by the presence of a cortical plate and total surface area of the implant fixture appears to be the decisive determinant for ISQ value.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22092387     DOI: 10.1111/j.1600-0501.2011.02285.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  14 in total

1.  A pre-clinical murine model of oral implant osseointegration.

Authors:  S Mouraret; D J Hunter; C Bardet; J B Brunski; P Bouchard; J A Helms
Journal:  Bone       Date:  2013-07-23       Impact factor: 4.398

2.  Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test.

Authors:  Dorjpalam Bayarchimeg; Hee Namgoong; Byung Kook Kim; Myung Duk Kim; Sungtae Kim; Tae-Il Kim; Yang Jo Seol; Yong Moo Lee; Young Ku; In-Chul Rhyu; Eun Hee Lee; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

3.  Bone cement grafting increases implant primary stability in circumferential cortical bone defects.

Authors:  Seung-Yun Shin; Seung-Il Shin; Seung-Beom Kye; Seok-Woo Chang; Jongrak Hong; Jun-Young Paeng; Seung-Min Yang
Journal:  J Periodontal Implant Sci       Date:  2015-02-25       Impact factor: 2.614

4.  Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading.

Authors:  Seong-Beom Kim; Pil-Young Yun; Sang-Yun Kim; Yang-Jin Yi; Ji-Yun Kim; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

5.  Primary implant stability in a bone model simulating clinical situations for the posterior maxilla: an in vitro study.

Authors:  Ho-Chyul Han; Hyun-Chang Lim; Ji-Youn Hong; Su-Jin Ahn; Ji-Young Han; Seung-Il Shin; Jong-Hyuk Chung; Yeek Herr; Seung-Yun Shin
Journal:  J Periodontal Implant Sci       Date:  2016-08-30       Impact factor: 2.614

6.  Influence of Implant Design (Cylindrical and Conical) in the Load Transfer Surrounding Long (13mm) and Short (7mm) Length Implants: A Photoelastic Analysis.

Authors:  Sergio Alexandre Gehrke; Victor Lourenço Frugis; Jamil Awad Shibli; Maria Piedad Ramirez Fernandez; José Eduardo Maté Sánchez de Val; José Luis Calvo Girardo; Silvio Taschieri; Stefano Corbella
Journal:  Open Dent J       Date:  2016-09-30

Review 7.  Clinical evaluation of osseointegration using resonance frequency analysis.

Authors:  Parth Satwalekar; Sandeep Nalla; Ramaswamy Reddy; Sheeba Glory Chowdary
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

8.  Six-implant-supported immediate fixed rehabilitation of atrophic edentulous maxillae with tilted distal implants.

Authors:  S Wentaschek; S Hartmann; C Walter; W Wagner
Journal:  Int J Implant Dent       Date:  2017-07-25

9.  Monitoring the Changes of Material Properties at Bone-Implant Interface during the Healing Process In Vivo: A Viscoelastic Investigation.

Authors:  Hsiang-Ho Chen; Wei-Yi Lai; Tze-Jian Chee; Ya-Hui Chan; Sheng-Wei Feng
Journal:  Biomed Res Int       Date:  2017-03-08       Impact factor: 3.411

10.  Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: pilot scan electron microscope and mechanical studies.

Authors:  André Walter; Heinz Winsauer; Jordi Marcé-Nogué; Sergi Mojal; Andreu Puigdollers
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.