Literature DB >> 22092369

Performance evaluation of the Sysmex pocH-100iV Diff hematology analyzer for analysis of canine, feline, equine, and bovine blood.

Barbara Riond1, Stefan Weissenbacher1, Regina Hofmann-Lehmann1, Hans Lutz1.   

Abstract

BACKGROUND: The Sysmex pocH-100iV Diff is an impedance hematology analyzer recently introduced for point-of-care use in veterinary practices in Europe.
OBJECTIVE: The purpose of this study was to validate the pocH-100iV Diff for analysis of blood samples from dogs, cats, horses, and cattle.
METHODS: Fresh EDTA-blood samples from healthy and ill dogs (115), cats (94), horses (91), and cattle (78) were analyzed on the pocH-100iV Diff and the Cell-Dyn 3500. Results of the automated WBC differential counts were compared with the manual differential counts for 77 dogs, 65 cats, 40 horses, and 46 cattle. HCT were compared with PCVs obtained by microhematocrit centrifugation. Furthermore, precision, linearity, carry-over, cell aging, and clinical relevance of the pocH-100iV Diff results were assessed.
RESULTS: Most of the CBC results obtained by the pocH-100iV Diff correlated well with those of the Cell-Dyn 3500. Slightly low correlation was observed for canine MCV and hemoglobin concentration. Lymphocytes correlated well in horses and cattle, but less well in cats and dogs. The mixed cell population termed "OTHRS" (all granulocytes and monocytes for horses and cattle; neutrophils, monocytes, and basophils for cats and dogs) correlated well in all tested species. The instrument overestimated feline and canine eosinophils. In cats, platelet counts showed a strong negative bias.
CONCLUSIONS: The overall performance of the pocH-100iV Diff was excellent with the noted limitations. The automated differential count can be used as screening tool in conjunction with evaluation of a blood smear.
© 2011 American Society for Veterinary Clinical Pathology.

Entities:  

Mesh:

Year:  2011        PMID: 22092369     DOI: 10.1111/j.1939-165X.2011.00372.x

Source DB:  PubMed          Journal:  Vet Clin Pathol        ISSN: 0275-6382            Impact factor:   1.180


  7 in total

1.  Effect of a trace mineral injection at weaning on growth, antioxidant enzymes activity, and immune system in Nellore calves.

Authors:  Marcelo Vedovatto; Camila da Silva Pereira; Ibrahim Miranda Cortada Neto; Philipe Moriel; Maria da Graça Morais; Gumercindo Loriano Franco
Journal:  Trop Anim Health Prod       Date:  2019-08-30       Impact factor: 1.559

2.  A hematologic key for bovine leukemia virus screening in Japanese black cattle.

Authors:  Masataka Akagami; Shoko Oya; Yuki Kashima; Satoko Seki; Yoshinao Ouchi; Yoko Hayama
Journal:  J Vet Diagn Invest       Date:  2019-05-03       Impact factor: 1.279

3.  Retroviral DNA--the silent winner: blood transfusion containing latent feline leukemia provirus causes infection and disease in naïve recipient cats.

Authors:  Stefanie Nesina; A Katrin Helfer-Hungerbuehler; Barbara Riond; Felicitas S Boretti; Barbara Willi; Marina L Meli; Paula Grest; Regina Hofmann-Lehmann
Journal:  Retrovirology       Date:  2015-12-21       Impact factor: 4.602

4.  First report of Cytauxzoon sp. infection in domestic cats in Switzerland: natural and transfusion-transmitted infections.

Authors:  Alice Nentwig; Marina L Meli; Johanna Schrack; Iris M Reichler; Barbara Riond; Corinne Gloor; Judith Howard; Regina Hofmann-Lehmann; Barbara Willi
Journal:  Parasit Vectors       Date:  2018-05-10       Impact factor: 3.876

5.  Monitoring of iron deficiency in calves by determination of serum ferritin in comparison with serum iron: A preliminary study.

Authors:  Jessica Joerling; Klaus Doll
Journal:  Open Vet J       Date:  2019-06-28

6.  Morphological Changes in Blood Cells in a Rat Model of Heatstroke: A Pilot Study.

Authors:  Toshiaki Iba; Tomohiro Sawada; Yutaka Kondo; Kenta Kondo; Jerrold H Levy
Journal:  J Clin Med       Date:  2022-08-17       Impact factor: 4.964

7.  Development and evaluation of a novel in-clinic automated hematology analyzer, ProCyte Dx, for canine erythrocyte indices, leukogram, platelet counts and reticulocyte counts.

Authors:  Yasuhito Fujino; Yoichi Nakamura; Hideaki Matsumoto; Kenjiro Fukushima; Masashi Takahashi; Koichi Ohno; Hajime Tsujimoto
Journal:  J Vet Med Sci       Date:  2013-07-01       Impact factor: 1.267

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.