Literature DB >> 22092157

The electrocoagulation/advanced oxidation treatment of the groundwater used for human consumption.

Visnja Orescanin1, Robert Kollar, Karlo Nad.   

Abstract

The purpose of this work was development and application of the purification system suitable for the treatment of groundwater used for human consumption, satisfying following criteria: (a) no need for external addition of the chemicals; (b) simultaneous removal of wide range of contaminants present in the treated water; (c) low sensitivity to the changes in the composition of the treated water; (d) high quality of treated water with regards to all measured parameters. Therefore the well water from the 60 m deep water layer situated near the city of Osijek (Eastern Croatia) with elevated values of heavy metals, color, turbidity, suspended solids, ammonia and organic contaminants was processed. Due to the complex composition of the treated water, the purification system required the combination of electroreduction/electrocoagulation, using iron and aluminum electrode plates followed by the simultaneous ozonation/UV treatment. The electroreduction/electrocoagulation approach was used for the removal of heavy metals, suspended solids, color and turbidity, while the organic contaminants and ammonia were removed by the ozonation/UV treatment. All measured parameters in the purified water were significantly lower compared to the regulated values. Under the optimum treatment conditions, the removal efficiencies for color, turbidity, nickel and arsenic were 100%. The removal efficiencies of V, Cr, Mn, Fe, Cu, Zn, Pb, ammonia, fluorides, sulfates and COD were 94.5%, 96.0%, 98.3%, 99.6%, 99.7%, 97.8%, 96.7%, 96,7%, 93.4%, 51.4%, 72.2% and 93.8%, respectively, increasing with the increased initial concentrations.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22092157     DOI: 10.1080/10934529.2011.623628

Source DB:  PubMed          Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng        ISSN: 1093-4529            Impact factor:   2.269


  1 in total

1.  Toxicity assessment of the water used for human consumption from the Cameron/Tuba City abandoned uranium mining area prior/after the combined electrochemical treatment/advanced oxidation.

Authors:  Goran Gajski; Višnja Oreščanin; Marko Gerić; Robert Kollar; Ivanka Lovrenčić Mikelić; Vera Garaj-Vrhovac
Journal:  Environ Sci Pollut Res Int       Date:  2014-08-05       Impact factor: 4.223

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.