Comparison of air-sealing characteristics of tapered- vs. cylindrical-shaped high-volume, low-pressure tube cuffs.

C Madjdpour1, J Mauch, M H Dave, N Spielmann, M Weiss.   

Abstract

BACKGROUND: This study aimed at comparing air-sealing characteristics of the new tapered-shaped tracheal tube cuffs with cylindrical tube cuffs.
METHODS: Tracheal tubes with tapered-shaped polyurethane (PU) and polyvinyl chloride (PVC) cuffs as well as standard cylindrical-shaped cuffs made of PU and PVC (Covidien, Athlone, Ireland) were investigated. A tracheal model attached to a test lung was intubated, and cuffs were inflated to 10, 15, 20, 25 and 30 cm H(2)O. The test lung was ventilated with intermittent positive pressure ventilation at peak inspiratory pressures (PIPs) of 20 and 25 cm H(2)O. Air leakage was assessed by spirometry and measurement of sevoflurane concentration passing the cuff at the upper cuff border using an anaesthetic gas analyser. Experiments were repeated four times with new tracheal tubes for each run. Statistical comparisons were done using Mann-Whitney U-test with level of significance at P < 0.05.
RESULTS: The tapered-shaped PVC tube cuff demonstrated a significantly lower air leakage determined by spirometry than the cylindrical-shaped cuff at both PIPs (20 and 25 cm H(2)O). Similarly, sevoflurane leakage was less with the tapered PVC cuff particularly at higher cuff pressures. With the PU cuff, reduction in air leakage by a tapered-shaped compared with a cylindrical-shaped tube cuff was not significant.
CONCLUSIONS: A tapered-shaped tube cuff considerably improves air-sealing characteristics of PVC tube cuffs and allows thereby reducing cuff pressure required for sufficient ventilation. In tube cuffs made of PU that exhibits superior sealing characteristics compared with PVC, a tapered shape failed to result in a further reduction of air leakage.
© 2011 The Authors Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22091784     DOI: 10.1111/j.1399-6576.2011.02542.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  11 in total

1.  Impact of tapered-cuff tracheal tube on microaspiration of gastric contents in intubated critically ill patients: a multicenter cluster-randomized cross-over controlled trial.

Authors:  Emmanuelle Jaillette; Christophe Girault; Guillaume Brunin; Farid Zerimech; Hélène Behal; Arnaud Chiche; Céline Broucqsault-Dedrie; Cyril Fayolle; Franck Minacori; Isabelle Alves; Stéphanie Barrailler; Julien Labreuche; Laurent Robriquet; Fabienne Tamion; Emmanuel Delaporte; Damien Thellier; Claire Delcourte; Alain Duhamel; Saad Nseir
Journal:  Intensive Care Med       Date:  2017-03-16       Impact factor: 17.440

2.  A Tapered Cuff Tracheal Tube Decreases the Need for Cuff Pressure Adjustment After Surgical Retraction During Anterior Cervical Spine Surgery: A Randomized Controlled, Double-Blind Trial.

Authors:  Yi-Shiuan Li; Elise Chia-Hui Tan; Yueh-Ju Tsai; Mercedes Susan Mandell; Shiang-Suo Huang; Ting-Yun Chiang; Wen-Cheng Huang; Wen-Kuei Chang; Ya-Chun Chu
Journal:  Front Med (Lausanne)       Date:  2022-06-29

3.  Impact of tracheal cuff shape on microaspiration of gastric contents in intubated critically ill patients: study protocol for a randomized controlled trial.

Authors:  Emmanuelle Jaillette; Guillaume Brunin; Christophe Girault; Farid Zerimech; Arnaud Chiche; Céline Broucqsault-Dedrie; Cyril Fayolle; Franck Minacori; Isabelle Alves; Stephanie Barrailler; Laurent Robriquet; Fabienne Tamion; Emmanuel Delaporte; Damien Thellier; Claire Delcourte; Alain Duhamel; Saad Nseir
Journal:  Trials       Date:  2015-09-25       Impact factor: 2.279

4.  Endotracheal Tube Cuff Pressure Assessment: Education May Improve but not Guarantee the Safety of Palpation Technique.

Authors:  Seyed Alireza Seyed Siamdoust; Masood Mohseni; Arash Memarian
Journal:  Anesth Pain Med       Date:  2015-06-22

5.  An in vitro comparison of tracheostomy tube cuffs.

Authors:  Seamus Maguire; Frances Haury; Korinne Jew
Journal:  Med Devices (Auckl)       Date:  2015-04-21

6.  Effects of lubrication on air-sealing performance of a pediatric cuffed tracheal tube.

Authors:  Hiroko Nishioka; Yutaka Usuda; Go Hirabayashi; Koichi Maruyama; Tomio Andoh
Journal:  BMC Anesthesiol       Date:  2017-09-19       Impact factor: 2.217

7.  Comparison of the cuff pressure of a TaperGuard endotracheal tube and a cylindrical endotracheal tube after lateral rotation of head during middle ear surgery: A single-blind, randomized clinical consort study.

Authors:  Eunkyung Choi; Yongmin Park; Younghoon Jeon
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

Review 8.  Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials.

Authors:  Wei Min Huang; Xu An Huang; Yan Ping Du; Liu Xia Li; Fang Fang Wu; Shao Qing Hong; Fang Xuan Tang; Zhang Qiang Ye
Journal:  Can Respir J       Date:  2019-01-22       Impact factor: 2.409

9.  Efficiency of a pneumatic device in controlling cuff pressure of polyurethane-cuffed tracheal tubes: a randomized controlled study.

Authors:  Emmanuelle Jaillette; Farid Zerimech; Julien De Jonckheere; Demosthenes Makris; Malika Balduyck; Alain Durocher; Alain Duhamel; Saad Nseir
Journal:  BMC Anesthesiol       Date:  2013-12-26       Impact factor: 2.217

10.  Comparison of the cuff pressures of a TaperGuard endotracheal tube during ipsilateral and contralateral rotation of the head: A randomized prospective study.

Authors:  Saeyoung Kim
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.