| Literature DB >> 22088119 |
Abstract
Abstract A Liquid Chromatography-Combustion (LC-C) Interface, based on a moving wire technique, has been built and tested. The LC effluent is deposited onto a transport wire, which carries the sample through solvent evaporation and combustion ovens. CO(2) from the combustion step is analysed in an isotope ratio mass spectrometer. Performance of the interface was tested by loop injections of sucrose and glucose into a liquid flow of methanol/water (80/20). Accuracy and precision of δ(13)C(PDB) < 1‰ was achieved for sample concentrations > 500 ng/ul (5μl loop), sufficient for studies at natural isotope ratios. In case of (13)C tracer applications the detection limit was determined to be about 20 pg carbon tracer (on wire).Entities:
Year: 1996 PMID: 22088119 DOI: 10.1080/10256019608036320
Source DB: PubMed Journal: Isotopes Environ Health Stud ISSN: 1025-6016 Impact factor: 1.675