Literature DB >> 22086569

Transcatheter aortic valve implantation: results of the current development and implantation of a new Brazilian prosthesis.

Diego Felipe Gaia1, José Honório Palma, Carolina Baeta Neves Duarte Ferreira, José Augusto Marcondes de Souza, Marcus Vinícius Gimenes, Murilo Teixeira Macedo, Márcio Rodrigo Martins, Enio Buffolo.   

Abstract

OBJECTIVE: Aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such risk can justify contraindication. Minimally invasive transcatheter aortic valve implantation has emerged as an alternative, with lower morbidity and mortality. The aim of this study was clinical, safety and efficacy assessment.
METHODS: Thirty-three high risk patients underwent transcatheter balloon expandable aortic valve implantation. Mean Logistic EuroScore risk was 39.30% and STS score 30.28%. Eight patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis were implanted trough the ventricular apex under rapid ventricular pacing or hemorrhagic shock. Echocardiographic and angiographic controls were performed.
RESULTS: Implant was feasible in 30 cases. Three conversions occured. There was only one case of operative death. Median transvalvular aortic gradient reduced from 43.58 mmHg to 10.54 mmHg. Left ventricular function improved in the first 7 postoperative days. Paravalvular aortic regurgitation was mild and present in 30.30%. One case presented major vascular complication and another one permanent pacemaker implant. One major stroke case occurred. Overall 30-day mortality was 18.18%.
CONCLUSION: The transapical implantation of catheter mounted bioprosthesis is a safe procedure with acceptable midterm results. Long term follow-up with increased sample power is mandatory in order to access hemodynamic, life quality and survival.

Entities:  

Mesh:

Year:  2011        PMID: 22086569     DOI: 10.5935/1678-9741.20110007

Source DB:  PubMed          Journal:  Rev Bras Cir Cardiovasc


  4 in total

1.  Balloon- or Self-Expandable TAVI: Clinical Equipoise?

Authors:  John Jose; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Interv Cardiol       Date:  2015-05

2.  A New Experimental Device for Transapical Access of the Aortic and Mitral Valves as well as the Aorta in its Various Segments.

Authors:  Leonardo Paim; José Honório Palma da Fonseca; Francismar Vidal de Arruda; Paulo Sampaio Gutierrez; Luiz Felipe Pinho Moreira; Fabio Biscegli Jatene
Journal:  Braz J Cardiovasc Surg       Date:  2017 May-Jun

3.  Initial experience of two national centers in transcatheter aortic prosthesis implantation.

Authors:  Sebastián Lluberas; Alexandre Abizaid; Dimytri Siqueira; Auristela Ramos; J Ribamar Costa; Magaly Arrais; Antônio Kambara; David Le Bihan; Amanda Sousa; J Eduardo Sousa
Journal:  Arq Bras Cardiol       Date:  2014-04       Impact factor: 2.000

4.  Transcatheter Aortic Valve Replacement: The Experience of One Brazilian Health Care Center.

Authors:  Fabiula Schwartz Azevedo; Marcelo Goulart Correa; Débora Holanda Gonçalves Paula; Alex Dos Santos Felix; Luciano Herman Juaçaba Belém; Ana Paula Chedid Mendes; Valeria Gonçalves Silva; Bruno Miranda Marques; Andrey José de Oliveira Monteiro; Clara Weksler; Alexandre Siciliano Colafranceschi; Daniel Arthur Barata Kasal
Journal:  Braz J Cardiovasc Surg       Date:  2018 Jan-Feb
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.