Literature DB >> 22083694

Reoperation for prosthetic ventricular septal defect patch endocarditis: long-term results with an autologous atrial septal patch.

Takako Miyazaki1, Masaaki Yamagishi, Hitoshi Yaku.   

Abstract

Treatment of prosthetic patch endocarditis after closure of a ventricular septal defect is challenging. It is essential to reduce inflammation and prevent recurrence of endocarditis. We report a successful case of reclosure of a ventricular septal defect using an autologous atrial septal patch taken from the fossa ovalis. There were no complications, and the long-term results were satisfactory. The autologous septal patch might be a promising material for prosthetic patch endocarditis.

Entities:  

Mesh:

Year:  2011        PMID: 22083694     DOI: 10.1007/s11748-010-0768-7

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  5 in total

1.  Atrial septum around the fossa ovalis: an ideal patch for the ventricular septal defect.

Authors:  Masaaki Yamagishi; Keisuke Shuntoh; Akiyuki Takahashi; Takeshi Shinkawa; Takako Miyazaki; Nobuo Kitamura
Journal:  J Thorac Cardiovasc Surg       Date:  2002-05       Impact factor: 5.209

2.  Bacterial endocarditis following surgery for congenital heart disease.

Authors:  L M LINDE; H L HEINS
Journal:  N Engl J Med       Date:  1960-07-14       Impact factor: 91.245

3.  Autologous pericardium for ventricular septal defect closure.

Authors:  P H Schoof; M G Hazekamp; K van Ulzen; M M Bartelings; J A Bruyn; W Helbing; H A Huysmans
Journal:  J Heart Valve Dis       Date:  1998-07

4.  Methicillin-resistant Staphylococcus aureus endocarditis following patch closure of a ventricular septal defect: report of a case.

Authors:  S Aoyagi; T Kawara; T Mizoguchi; F Ando; T Yanai; E Yamamoto; K Suzuki
Journal:  Surg Today       Date:  1994       Impact factor: 2.549

5.  Infective endocarditis following patch closure of ventricular septal defect: a cross-sectional Doppler echocardiographic study.

Authors:  S Shrivastava; S Radhakrishnan
Journal:  Int J Cardiol       Date:  1989-10       Impact factor: 4.164

  5 in total
  1 in total

1.  Late infectious endocarditis of surgical patch closure of atrial septal defects diagnosed by 18F-fluorodeoxyglucose gated cardiac computed tomography (18F-FDG-PET/CT): a case report.

Authors:  Estelle Honnorat; Piseth Seng; Alberto Riberi; Gilbert Habib; Andreas Stein
Journal:  BMC Res Notes       Date:  2016-08-24
  1 in total