Literature DB >> 22082509

Gait analysis using 3D accelerometry in horses sedated with xylazine.

F J López-Sanromán1, R Holmbak-Petersen, I Santiago, I A Gómez de Segura, E Barrey.   

Abstract

The aim of the present study was to verify the efficacy and sensitivity of an accelerometric device in detecting and quantifying the degree of movement alteration produced in horses sedated with xylazine. Horses (n=6) were randomly administered either xylazine or a control by intravenous injection, with at least 1 week between each treatment. A triaxial accelerometric device was used for the accelerometric gait assessment 15 min before (baseline) and 5, 15, 30, 45, 60, 75, 90, 105 and 120 min after each treatment. Eight different accelerometric parameters were calculated, including speed, stride frequency, stride length, regularity, dorsoventral power, propulsion power, mediolateral power and total power, with the force of acceleration and the dorsoventral, mediolateral and craniocaudal (propulsive) parts of the power then calculated. Administration of xylazine decreased many of the parameters investigated, with significant differences for speed, stride frequency, dorsoventral power, propulsion power and total power at 5, 15, 30 and 45 min after injection. There were no significant differences in stride length values at any time point. Decreases in regularity values were evident with significant differences at every time point from 5 to 120 min following xylazine injection. Force values were also significantly reduced from 5 to 30 min after treatment and a redistribution of the total power was observed 5 min after injection as the mediolateral power increased significantly, while the dorsoventral power decreased. Accelerometry offers a practical, accurate, easy to use, portable and low cost method of objectively monitoring gait abnormalities at the walk in horses after sedation with xylazine.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22082509     DOI: 10.1016/j.tvjl.2011.10.012

Source DB:  PubMed          Journal:  Vet J        ISSN: 1090-0233            Impact factor:   2.688


  5 in total

1.  Morphine with or without Acepromazine in Horses: A Kinematic Evaluation.

Authors:  F Javier López-Sanromán; G Montes Freilich; D Gómez-Cisneros; J Izquierdo-Moreno; M Varela Del Arco; G Manso-Díaz
Journal:  Animals (Basel)       Date:  2022-05-06       Impact factor: 3.231

2.  Combined Effects of Water Depth and Velocity on the Accelerometric Parameters Measured in Horses Exercised on a Water Treadmill.

Authors:  Aritz Saitua; Mireya Becero; David Argüelles; Cristina Castejón-Riber; Antonia Sánchez de Medina; Katy Satué; Ana Muñoz
Journal:  Animals (Basel)       Date:  2020-02-03       Impact factor: 2.752

3.  Acceleration Gait Measures as Proxies for Motor Skill of Walking: A Narrative Review.

Authors:  Pritika Dasgupta; Jessie VanSwearingen; Alan Godfrey; Mark Redfern; Manuel Montero-Odasso; Ervin Sejdic
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2021-03-01       Impact factor: 3.802

4.  Accelerometric Changes before and after Capacitive Resistive Electric Transfer Therapy in Horses with Thoracolumbar Pain Compared to a SHAM Procedure.

Authors:  David Argüelles; Mireya Becero; Ana Muñoz; Aritz Saitua; Toni Ramón; Eduard Gascón; Antonia Sánchez de Medina; Marta Prades
Journal:  Animals (Basel)       Date:  2020-12-05       Impact factor: 2.752

5.  Variation in gait parameters used for objective lameness assessment in sound horses at the trot on the straight line and the lunge.

Authors:  A M Hardeman; F M Serra Bragança; J H Swagemakers; P R van Weeren; L Roepstorff
Journal:  Equine Vet J       Date:  2019-02-12       Impact factor: 2.888

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.