Literature DB >> 22078232

A sub-two minutes method for monoclonal antibody-aggregate quantification using parallel interlaced size exclusion high performance liquid chromatography.

Patrick Diederich1, Sigrid K Hansen, Stefan A Oelmeier, Bianca Stolzenberger, Jürgen Hubbuch.   

Abstract

In process development and during commercial production of monoclonal antibodies (mAb) the monitoring of aggregate levels is obligatory. The standard assay for mAb aggregate quantification is based on size exclusion chromatography (SEC) performed on a HPLC system. Advantages hereof are high precision and simplicity, however, standard SEC methodology is very time consuming. With an average throughput of usually two samples per hour, it neither fits to high throughput process development (HTPD), nor is it applicable for purification process monitoring. We present a comparison of three different SEC columns for mAb-aggregate quantification addressing throughput, resolution, and reproducibility. A short column (150 mm) with sub-two micron particles was shown to generate high resolution (~1.5) and precision (coefficient of variation (cv)<1) with an assay time below 6 min. This column type was then used to combine interlaced sample injections with parallelization of two columns aiming for an absolute minimal assay time. By doing so, both lag times before and after the peaks of interest were successfully eliminated resulting in an assay time below 2 min. It was demonstrated that determined aggregate levels and precision of the throughput optimized SEC assay were equal to those of a single injection based assay. Hence, the presented methodology of parallel interlaced SEC (PI-SEC) represents a valuable tool addressing HTPD and process monitoring.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22078232     DOI: 10.1016/j.chroma.2011.09.086

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  RPLC of intact proteins using sub-0.5 μm particles and commercial instrumentation.

Authors:  Benjamin J Rogers; Robert E Birdsall; Zhen Wu; Mary J Wirth
Journal:  Anal Chem       Date:  2013-07-02       Impact factor: 6.986

Review 2.  Quality assessment and optimization of purified protein samples: why and how?

Authors:  Bertrand Raynal; Pascal Lenormand; Bruno Baron; Sylviane Hoos; Patrick England
Journal:  Microb Cell Fact       Date:  2014-12-30       Impact factor: 5.328

Review 3.  Different Stationary Phase Selectivities and Morphologies for Intact Protein Separations.

Authors:  A Astefanei; I Dapic; M Camenzuli
Journal:  Chromatographia       Date:  2016-09-23       Impact factor: 2.044

4.  Size-Exclusion Chromatography for the Analysis of Protein Biotherapeutics and their Aggregates.

Authors:  Paula Hong; Stephan Koza; Edouard S P Bouvier
Journal:  J Liq Chromatogr Relat Technol       Date:  2012-11-30       Impact factor: 1.467

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.