Fluorous solvents are the most nonpolar, nonpolarizable phases known, whereas ions are inherently polar. This makes it difficult to create salts that are soluble in a fluorous solvent. Here we present the synthesis and characterization of a new fluorophilic phosphonium salt, tris{3,5-bis[(perfluorooctyl)propyl]phenyl}methylphosphonium methyl sulfate. The salt has a solubility of at least 14 mM in perfluoro(perhydrophenanthrene), perfluoro(methylcyclohexane), and perfluorohexanes. It also shows immediate potential for use as a phase-transfer catalyst in fluorous biphasic catalysis, but in this work it is used as an anion exchanger site in the first potentiometric fluorous-membrane anion-selective electrode. The membrane sensor exhibited the exceptional selectivity of 3.9 × 10(10) to 1 for perfluorooctanesulfonate over chloride, and of 2.5 × 10(7) to 1 for perfluorooctanoate over chloride. With improvements to the sensor's detection limit and lifetime, it has the potential to be an attractive alternative to the expensive, time-consuming methods currently employed for measurement of perfluorinated acids.
Fluorous solvents are the most nonpolar, nonpolarizable phases known, whereas ions are inherently polar. This makes it difficult to create pan class="Chemical">salts that are soluble in a fluorous solvent. Here we present the synthesis and characterization of a new fluorophilic phosphonium salt, tris{3,5-bis[(perfluorooctyl)propyl]phenyl}methylphosphonium methyl sulfate. The salt has a solubility of at least 14 mM in perfluoro(perhydrophenanthrene), perfluoro(methylcyclohexane), and perfluorohexanes. It also shows immediate potential for use as a phase-transfer catalyst in fluorous biphasic catalysis, but in this work it is used as an anion exchanger site in the first potentiometric fluorous-membrane anion-selective electrode. The membrane sensor exhibited the exceptional selectivity of 3.9 × 10(10) to 1 for perfluorooctanesulfonate over chloride, and of 2.5 × 10(7) to 1 for perfluorooctanoate over chloride. With improvements to the sensor's detection limit and lifetime, it has the potential to be an attractive alternative to the expensive, time-consuming methods currently employed for measurement of perfluorinated acids.
Authors: Haijun Jiao; Sylvie Le Stang; Tibor Soós; Ralf Meier; Klaus Kowski; Paul Rademacher; Laleh Jafarpour; Jean-Benoit Hamard; Steven P Nolan; J A Gladysz Journal: J Am Chem Soc Date: 2002-02-20 Impact factor: 15.419
Authors: Chun-Ze Lai; Melissa A Fierke; Rosenildo Corrêa da Costa; John A Gladysz; Andreas Stein; Philippe Bühlmann Journal: Anal Chem Date: 2010-09-15 Impact factor: 6.986
Authors: Chun-Ze Lai; Secil S Koseoglu; Elizabeth C Lugert; Paul G Boswell; József Rábai; Timothy P Lodge; Philippe Bühlmann Journal: J Am Chem Soc Date: 2009-02-04 Impact factor: 15.419